Print Report | Back to Sample Detail

Sample Record for 2025-06-09-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-06-09-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 06/09/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/16/2025
The quantity of what the sample constitutes: 3 Heats
A brief description of the sample: .6" ASTM A416 Uncoated Seven Wire Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire Products Corporation

Material Information

Comments:
Reel/Coil/Pack Number(s): S337004-1 S337015-6 S380830-1
Number of Coils:
Group Number:
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0509124 S0546224-2 S0521425
Mfg. Lot Number(s): N/A
Manufacturer(s): Sumiden Wire Products Corporation

Test Results

Test 1 of 1

DIME Test ID: 2025-06-09-1-1
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/01/2025
Date Tested: 07/01/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 9
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0509124S337004-1.217607205596028.051.748Atlas
S0509124S337004-1.217600005566028.651.7Atlas
S0509124S337004-1.217602005542029.441.87Atlas
S0546224-2S337015-6.217605905547028.341.88Atlas
S0546224-2S337015-6.217607705590028.881.14Atlas
S0546224-2S337015-6.217606805547028.351.91Atlas
S0521425S380830-1.217602005408028.081.86Atlas
S0521425S380830-1.217608205365027.682.07Atlas
S0521425S380830-1.217611105510028.722.04Atlas
UTM NA
Temperature 0 f
Extensometers NA