Project Information

Project ID: 995057 DEA: 07321604 EFIS: 0716000049 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-1-0.0/18.0
Work Description: COLD PLANE AND OVERLAY AC PAVEMENT AND UPGRADE ADA CURB RAMPS.
Location Description: LOS ANGELES COUNTY FROM STUDEBAKER ROAD TO PASEO DE LAS DELICIAS
Contractor Name: R.J. NOBLE COMPANY
Contractor Address: 15505 E. Lincoln Ave, Orange, CA 92865
Resident Engineer: Thang Ton Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-05-28-79
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 05/28/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/06/2025
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble Orange

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2025-05-28-79-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 07/02/2025
Date Tested: 06/05/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 65 C
Softening Point Sample 2 65 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2025-05-28-79-2
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 07/02/2025
Date Tested: 06/06/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 34 0.1 mm

Test 3 of 3

DIME Test ID: 2025-05-28-79-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 07/02/2025
Date Tested: 06/06/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 3 mm
Final Dial reading (F1) 67 mm
Ball Penetration (P2) 3 mm
Final Dial reading (F2) 68 mm
Ball Penetration (P3) 2 mm
Final Dial reading (F3) 68 mm
Resilience 1 36 %
Resilience 2 35 %
Resilience 3 34 %
Average Resilience 35 %
Minutes Reaction no data