Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000272 DEA: 100V4804 EFIS: 1013000264
QA Service Level: 1
DIST-CO-RTE-PM: 10-CAL-26-21.8/30.3
Work Description: SLOPE STABILIZATION AND CONSTRUCT RETAINING WALL.
Location Description: CALAVERAS COUNTY NEAR MOKELUMNE HILL AT VARIOUS LOCATIONS FROM 3.6 MILES EAST OF ROUTE 49 TO 0.9 MILE WEST OF WOODHOUSE MINE ROAD
Contractor Name: VIKING CONSTRUCTION COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: Jonathan Ngai Structure Rep.: Conor Hennessy
DIME Sample ID: 2025-04-30-67
TL Number from the TL Form: 83262
Sample Submitted By Organization: CT SC - 3665 - Shingle Springs
Sample Organization Contact: (530) 821-8266
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/30/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/05/2025
The quantity of what the sample constitutes: 6 cylinders
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 30-E0004
Structure name: Wall 2
The fabricator/manufacturer/facility name: 7-11 Materials
The concrete mix design number: 800886A6
The truck number from where the sample was collected: 84008
The batch plant ticket number from where the sample was collected: 920895
Concrete batch plant:
The fabricator/manufacturer designation for the sample: 7-11 Materials
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled: Wall 2
From Lot No.:
Bag Lot No.:
DIME Test ID: 2025-04-30-67-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/05/2025
Date Tested: 06/05/2025
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Apparent mass of submerged cylinder 1
|
no data0 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
3.99 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.5 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4860 psi
|
|
Maximum load on cylinder 1
|
60430 lb
|
|
Maximum load on cylinder 2
|
59780 lb
|
|
Maximum load on cylinder 3
|
62640 lb
|
|
Compressive strength of cylinder 1
|
4810.0 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
4780.0 psi
|
|
Compressive strength of cylinder 3
|
4980 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
21 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|
DIME Test ID: 2025-04-30-67-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/05/2025
Date Tested: 06/05/2025
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Apparent mass of submerged cylinder 1
|
no data0 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4900 psi
|
|
Maximum load on cylinder 1
|
62480 lb
|
|
Maximum load on cylinder 2
|
61710 lb
|
|
Maximum load on cylinder 3
|
60540 lb
|
|
Compressive strength of cylinder 1
|
4970.0 psi
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Compressive strength of cylinder 2
|
4910.0 psi
|
|
Compressive strength of cylinder 3
|
4820 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|
DIME Test ID: 2025-04-30-67-3
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 06/06/2025
Date Tested: 04/30/2025
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2025-04-30-67-4
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 06/06/2025
Date Tested: 04/30/2025
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2025-04-30-67-5
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 06/06/2025
Date Tested: 04/30/2025
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified: