Project Information

Project ID: 994978 DEA: 09379504 EFIS: 0919000009 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-5709-
Work Description: CONSTRUCT BUILDING AND PLACE HMA.
Location Description: INYO COUNTY AT INDEPENDENCE AT THE INDEPENDENCE MAINTENANCE STATION AT 665 NORTH EDWARDS STREET
Contractor Name: FEC FUTURE CONTRACTORS AND ENGINEERS INC
Contractor Address: 184 Technology Drive, Irvine, CA 92618
Resident Engineer: George Elzawy Structure Rep.: Derek Armon

Sample Information

DIME Sample ID: 2025-06-03-36
TL Number from the TL Form: JMF-1
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 06/03/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/03/2025
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: 3/4" Coldfeed & RAP
From where was the sample collected: Source
Laboratory sample identification: 4611
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite 5 Bridges Plant Bishop

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-14-0001
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Sample Device at Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 6

DIME Test ID: 2025-06-03-36-1
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 06/04/2025
Date Tested: 06/03/2025
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: JMF-1
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 75

Test 2 of 6

DIME Test ID: 2025-06-03-36-2
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 06/04/2025
Date Tested: 06/04/2025
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: JMF-1 Final Combined Gradation with RAP
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve no data0 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 95 %
Cumulative percent passing the 1/2 in. sieve 82 %
Cumulative percent passing the 3/8 in. sieve 74 %
Cumulative percent passing the #4 sieve 55 %
Cumulative percent passing the #8 sieve 39 %
Cumulative percent passing the #16 sieve 28 %
Cumulative percent passing the #30 sieve 20 %
Cumulative percent passing the #50 sieve 13 %
Cumulative percent passing the #100 sieve 7 %
Cumulative percent passing the #200 sieve 4.1 %

Test 3 of 6

DIME Test ID: 2025-06-03-36-3
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 06/04/2025
Date Tested: 06/03/2025
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: JMF-1 RAP
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? Yes
Aggregate correction factor for the 2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/4 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/8 in. sieve (% passing) -0.2 %
Aggregate correction factor for the #4 sieve (% passing) -7.4 %
Aggregate correction factor for the #8 sieve (% passing) -9.9 %
Aggregate correction factor for the #16 sieve (% passing) -4.3 %
Aggregate correction factor for the #30 sieve (% passing) -4.1 %
Aggregate correction factor for the #50 sieve (% passing) -3.4 %
Aggregate correction factor for the #100 sieve (% passing) -2.5 %
Aggregate correction factor for the #200 sieve (% passing) -1.6 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 73 %
Cumulative percent passing the #8 sieve 51 %
Cumulative percent passing the #16 sieve 41 %
Cumulative percent passing the #30 sieve 30 %
Cumulative percent passing the #50 sieve 20 %
Cumulative percent passing the #100 sieve 13 %
Cumulative percent passing the #200 sieve 8.5 %

Test 4 of 6

DIME Test ID: 2025-06-03-36-4
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 06/04/2025
Date Tested: 06/03/2025
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: JMF-1
Test Result Compliance: complies
Additional Comments When Verified:
Method 2 - Individual Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced
Weighted average percentage of fractured, coarse, 2 faced particles 99.1 %
Weighted average percentage of fractured, coarse, 1 faced particles 97.8 %

Test 5 of 6

DIME Test ID: 2025-06-03-36-5
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 06/04/2025
Date Tested: 06/03/2025
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: JMF-1
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation B
Mass of sample on No.12 sieve (after 500 revolutions) 3520 grams
Percent loss after 100 revolutions 7 %
Percent loss after 500 revolutions 30 %

Test 6 of 6

DIME Test ID: 2025-06-03-36-6
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 06/04/2025
Date Tested: 06/03/2025
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: JMF-1
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.622
Average uncompacted voids 47.6 %