Print Report | Back to Sample Detail

Sample Record for 2025-05-22-46

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994903 DEA: 11430244 EFIS: 1118000033 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-125-9.3/13.0
Work Description: PLACE HMA, RHMA, SLAB REPLACEMENT, AND ELECTRICAL WORK.
Location Description: SAN DIEGO COUNTY IN AND NEAR LEMON GROVE FROM 0.3 MILE SOUTH OF ELKELTON PLACE UNDERCROSSING TO 0.2 MILE SOUTH OF ROUTE 125/94 SEPARATION
Contractor Name: HAZARD CONSTRUCTION ENGR LLC
Contractor Address: 10529 Vine Street, Lakeside, CA 92040
Resident Engineer: Sultan Ghazialam Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-05-22-46
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/22/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/23/2025
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: Plant Samples
From where was the sample collected: Source
Laboratory sample identification: 25-05-22-46-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 226110 Otay SJR
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 2

DIME Test ID: 2025-05-22-46-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/04/2025
Date Tested: 06/04/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target 7.5% Complies - 7.26
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3931.8 g
Mass of the specimen and specimen basket assembly prior to ignition 5982.7 g
Mass of HMA Sample prior to ignition 2050.9 g
Corrected Asphalt Binder Content 7.26 %
Mass Loss 164.3 g
Mass of aggregate remaining after ignition 1886.6 g
Correction Factor (Percent by mass of HMA Specimen) 0.75 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2025-05-22-46-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/09/2025
Date Tested: 06/06/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target = 2.418 1st Test - 2.460 2nd Test - 2.450 Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7475.6 grams
Mass of oven-dry sample in air for Sample 1 2508.1 grams
Mass of container filled with the sample and water for Sample 1 8960 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.45
Theoretical maximum density at 25°C (77°F) 152.5 lb/ft^3