Print Report | Back to Sample Detail

Sample Record for 2025-05-20-68

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993529 DEA: 11430514 EFIS: 1119000008 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-15-R31.3/R37.1
Work Description: CRCP, FIBER OPTIC CABLE, AND HMA.
Location Description: SAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING
Contractor Name: Security Paving Company, Inc.
Contractor Address: 13170 Telfair Ave, Sylmar, CA 91342
Resident Engineer: Jason Alsheikh Structure Rep.: Tan Cao

Sample Information

DIME Sample ID: 2025-05-20-68
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/20/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/28/2025
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: Plant Sample
From where was the sample collected: Source
Laboratory sample identification: 25-05-20-68-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 23417005SR MM
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 2

DIME Test ID: 2025-05-20-68-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/03/2025
Date Tested: 06/02/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target - 4.3%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4030.9 g
Mass of the specimen and specimen basket assembly prior to ignition 6068.4 g
Mass of HMA Sample prior to ignition 2037.5 g
Corrected Asphalt Binder Content 4.8 %
Mass Loss 101.2 g
Mass of aggregate remaining after ignition 1936.3 g
Correction Factor (Percent by mass of HMA Specimen) 0.17 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2025-05-20-68-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/03/2025
Date Tested: 06/02/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target - 2.510
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7475.6 grams
Mass of oven-dry sample in air for Sample 1 2532.3 grams
Mass of container filled with the sample and water for Sample 1 9008.6 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.534
Theoretical maximum density at 25°C (77°F) 157.7 lb/ft^3