Sample Record for 2025-05-29-4
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994525 DEA: 031H9904 EFIS: 0317000043
QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA,NEV-80-68.3/69.7,0.0/R2.7
Work Description: RDWY EXC, PLACE HMA & JPCP, SLAB REPLACEMENT & POLYESTER CONC OVERLAY.
Location Description: PLACER AND NEVADA COUNTIES NEAR KINGVALE FROM 0.3 MILE WEST OF TROY UNDERCROSSING TO 0.2 MILE EAST OF SODA SPRINGS OVERCROSSING
Contractor Name: A. TEICHERT & SON INC DBA TEICHERT CONSTRUCTION
Contractor Address: 4401 Duluth Avenue, Rocklin, CA 95765
Resident Engineer: Randie Babbini Structure Rep.: Carl Anderson
Sample Information
DIME Sample ID: 2025-05-29-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 05/29/2025
Date that the sample was received by the laboratory/organization performing the testing: 06/03/2025
The quantity of what the sample constitutes: 2
A brief description of the sample: ASTM 775 Epoxy Coated Bar
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Coating
Material Information
Rebar Heat Number(s): 136025
Rebar Epoxy Batch Number(s): CH3374UX
Rebar Coating Specification: ASTM A775
Rebar Size (#): #4
Rebar Coating Color: Green
Rebar Manufacturer: Cascade Steel Rolling Mills Inc
Rebar Coater: Rebar Coating Inc in Eugene OR
Rebar Powder Manufacturer:
Release Number:
Quality Assurance Code:
Test Results
Test 1 of 2
DIME Test ID: 2025-05-29-4-1
Test Method: ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 06/11/2025
Date Tested: 06/10/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
First Bar Mean
|
9.31
|
|
Second Bar Mean
|
8.45
|
|
Lower spec. limit LSL
|
7
|
|
Upper spec. limit USL
|
12
|
|
Bar # for First Bar
|
1
|
|
Bar # for Second Bar
|
2
|
|
Total mean value
|
8.88
|
|
Total number of values less than LSL
|
no data
|
|
Total number of values greater than USL
|
no data
|
Test 2 of 2
DIME Test ID: 2025-05-29-4-2
Test Method: ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 06/11/2025
Date Tested: 06/10/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Total Number of Holiday
|
no data0
|
|
Total Length
|
5
|
|
Holidays Per Linear Foot of Bar
|
no data0 holiday per ft
|
|
Holiday Test Pass/Fail
|
Pass
|
|
Bend Test Pass/Fail
|
Pass
|