Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993868 DEA: 050C7324 EFIS: 0512000228
QA Service Level: 1
DIST-CO-RTE-PM: 05-SCR-1-13.4/14.9
Work Description: CONSTRUCT PEDESTRIAN OVERCROSSING AND AUXILIARY LANE.
Location Description: SANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM 0.2 MILE SOUTH OF 41ST AVENUE OVERCROSSING TO 0.2 MILE NORTH OF SOQUEL DRIVE OVERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 585 BEACH STREET, WATSONVILLE CA 95076
Resident Engineer: Gareth Gill Structure Rep.: Alejandro (Alex) Gomez
DIME Sample ID: 2025-05-27-2
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3675 - Santa Cruz Field Office
Sample Organization Contact: (925) 285-1217
Type of Sample: Acceptance
Type of Material: Roadway/Bridge Surface
Sample Taken Date: 05/27/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/27/2025
The quantity of what the sample constitutes: Multiple Lanes
A brief description of the sample: Skid Testing Request
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Ennis-Flint and Swarco
Pavement Surface Type: Methacrylate Resin
Type of Traffic Control Provided: Stationary Lane Closure
DIST-CO-RTE: 05-SCr-001
Direction of Travel:
Post Mile:
Lanes to be Tested: Shoulder
Station:
DIME Test ID: 2025-05-27-2-1
Test Method: CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Verified Date: 05/30/2025
Date Tested: 05/30/2025
Submitted By Organization: CT HQ - FFS - Skid Testing
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: SB1. SO CAL GORGE
Test Result Compliance: complies
Additional Comments When Verified:
|
Pavement or Bridge Deck?
|
Pavement
|
|
Average Coefficient of Friction
|
0.49
|
DIME Test ID: 2025-05-27-2-2
Test Method: CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Verified Date: 05/30/2025
Date Tested: 05/30/2025
Submitted By Organization: CT HQ - FFS - Skid Testing
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: NB1 SO CAL STRAIGHT
Test Result Compliance: complies
Additional Comments When Verified:
|
Pavement or Bridge Deck?
|
Pavement
|
|
Average Coefficient of Friction
|
0.45
|
DIME Test ID: 2025-05-27-2-3
Test Method: CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Verified Date: 05/30/2025
Date Tested: 05/30/2025
Submitted By Organization: CT HQ - FFS - Skid Testing
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: SB1 41ST GORGE
Test Result Compliance: complies
Additional Comments When Verified:
|
Pavement or Bridge Deck?
|
Pavement
|
|
Average Coefficient of Friction
|
0.35
|
DIME Test ID: 2025-05-27-2-4
Test Method: CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Verified Date: 05/30/2025
Date Tested: 05/30/2025
Submitted By Organization: CT HQ - FFS - Skid Testing
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: SB1 41ST STRAIGHT
Test Result Compliance: complies
Additional Comments When Verified:
|
Pavement or Bridge Deck?
|
Pavement
|
|
Average Coefficient of Friction
|
0.36
|
DIME Test ID: 2025-05-27-2-5
Test Method: CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Verified Date: 05/30/2025
Date Tested: 05/30/2025
Submitted By Organization: CT HQ - FFS - Skid Testing
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: NB1 41ST STRAIGHT
Test Result Compliance: complies
Additional Comments When Verified:
|
Pavement or Bridge Deck?
|
Pavement
|
|
Average Coefficient of Friction
|
0.45
|
DIME Test ID: 2025-05-27-2-6
Test Method: CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Verified Date: 05/30/2025
Date Tested: 05/30/2025
Submitted By Organization: CT HQ - FFS - Skid Testing
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: NB1 41ST CIRCLE
Test Result Compliance: complies
Additional Comments When Verified:
|
Pavement or Bridge Deck?
|
Pavement
|
|
Average Coefficient of Friction
|
0.45
|
DIME Test ID: 2025-05-27-2-7
Test Method: CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Verified Date: 05/30/2025
Date Tested: 05/30/2025
Submitted By Organization: CT HQ - FFS - Skid Testing
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: NB1 SO. CAL
Test Result Compliance: complies
Additional Comments When Verified:
|
Pavement or Bridge Deck?
|
Pavement
|
|
Average Coefficient of Friction
|
0.42
|