Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-10-08-153
TL Number from the TL Form:
Sample Submitted By Organization: Jaxon Enterprises - Deer Creek Rock & Asphalt
Sample Organization Contact: (559) 793-0903
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 10/08/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/08/2024
The quantity of what the sample constitutes: JMF
A brief description of the sample: Cold Feed
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Deer Creek Asphalt
Source Identification (SMARA, name of Pit or Job Site): 91-54-0021
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Lab Blend
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
DIME Test ID: 2024-10-08-153-1
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: Jaxon Enterprises - Deer Creek Rock & Asphalt
Organization Address: 27671 Avenue 120,
Organization City: Porterville
Organization State: CA
Organization Zipcode: 93257
Organization Email: jordanb@jaxonaggregates.com
Organization Phone: (530) 227-0982
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
|
Method
|
1 - Combined Fracture Determination
|
|
Aggregate Size and Fracture Type
|
Coarse 1 and 2 Faced and Fine 1 Faced
|
|
Percentage of fractured, coarse, 2 faced particles tested
|
100 %
|
|
Percentage of fractured, coarse, 1 faced particles tested
|
100 %
|
|
Percentage of fractured, fine, 1 faced particles tested
|
99.8 %
|
DIME Test ID: 2024-10-08-153-2
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: Jaxon Enterprises - Deer Creek Rock & Asphalt
Organization Address: 27671 Avenue 120,
Organization City: Porterville
Organization State: CA
Organization Zipcode: 93257
Organization Email: jordanb@jaxonaggregates.com
Organization Phone: (530) 227-0982
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
|
Grading designation
|
no data
|
|
Percent loss after 100 revolutions
|
6 %
|
|
Percent loss after 500 revolutions
|
19 %
|
DIME Test ID: 2024-10-08-153-3
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: Jaxon Enterprises - Deer Creek Rock & Asphalt
Organization Address: 27671 Avenue 120,
Organization City: Porterville
Organization State: CA
Organization Zipcode: 93257
Organization Email: jordanb@jaxonaggregates.com
Organization Phone: (530) 227-0982
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2024-10-08-153-4
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: Jaxon Enterprises - Deer Creek Rock & Asphalt
Organization Address: 27671 Avenue 120,
Organization City: Porterville
Organization State: CA
Organization Zipcode: 93257
Organization Email: jordanb@jaxonaggregates.com
Organization Phone: (530) 227-0982
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
|
What test method is performed?
|
Method A
|
|
Bulk dry specific gravity
|
no data
|
|
Average uncompacted voids
|
46.4 %
|
DIME Test ID: 2024-10-08-153-5
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: Jaxon Enterprises - Deer Creek Rock & Asphalt
Organization Address: 27671 Avenue 120,
Organization City: Porterville
Organization State: CA
Organization Zipcode: 93257
Organization Email: jordanb@jaxonaggregates.com
Organization Phone: (530) 227-0982
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
|
Method
|
B
|
|
Determination
|
By Mass
|
|
Dimensional ratio used
|
5:1
|
|
Weighted percentage of particles (by mass) that were flat and elongated
|
1 %
|
|
Weighted percentage of particles (by mass) that were not flat and elongated
|
no data
|
DIME Test ID: 2024-10-08-153-6
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: Jaxon Enterprises - Deer Creek Rock & Asphalt
Organization Address: 27671 Avenue 120,
Organization City: Porterville
Organization State: CA
Organization Zipcode: 93257
Organization Email: jordanb@jaxonaggregates.com
Organization Phone: (530) 227-0982
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
Oops.. looks like no test results have been submitted for the test.
DIME Test ID: 2024-10-08-153-7
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: Jaxon Enterprises - Deer Creek Rock & Asphalt
Organization Address: 27671 Avenue 120,
Organization City: Porterville
Organization State: CA
Organization Zipcode: 93257
Organization Email: jordanb@jaxonaggregates.com
Organization Phone: (530) 227-0982
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
|
Basis for relative density testing
|
Bulk
|
|
Specific Gravity
|
2.957
|
|
Absorption
|
0.7 %
|
DIME Test ID: 2024-10-08-153-8
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: Jaxon Enterprises - Deer Creek Rock & Asphalt
Organization Address: 27671 Avenue 120,
Organization City: Porterville
Organization State: CA
Organization Zipcode: 93257
Organization Email: jordanb@jaxonaggregates.com
Organization Phone: (530) 227-0982
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
|
Bulk specific gravity
|
2.845
|
|
Bulk specific gravity (SSD Basis)
|
2.899
|
|
Apparent specific gravity
|
3.006
|
|
Absorption
|
1.9 %
|
DIME Test ID: 2024-10-08-153-9
Test Method: AASHTO T100-15: Standard Method of Test for Specific Gravity of Soils (Specific Gravity)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: Jaxon Enterprises - Deer Creek Rock & Asphalt
Organization Address: 27671 Avenue 120,
Organization City: Porterville
Organization State: CA
Organization Zipcode: 93257
Organization Email: jordanb@jaxonaggregates.com
Organization Phone: (530) 227-0982
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2024-10-08-153-10
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: Jaxon Enterprises - Deer Creek Rock & Asphalt
Organization Address: 27671 Avenue 120,
Organization City: Porterville
Organization State: CA
Organization Zipcode: 93257
Organization Email: jordanb@jaxonaggregates.com
Organization Phone: (530) 227-0982
General Comments for this Test: Submitted from JMF - Michael Davis
Test Result Compliance:
Additional Comments When Verified:
|
Which test procedure(s) is/are used?
|
Procedure A and Procedure B
|
|
Was strict temperature control maintained?
|
no data
|
|
What type of water was used?
|
no data
|
|
Durability Index (coarse)
|
80
|
|
Durability Index (fine)
|
80
|