Print Report | Back to Sample Detail

Sample Record for 2025-05-21-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000369 DEA: 09378804 EFIS: 0919000002 QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO-395-R9.8/R12.6
Work Description: PLACE HMA AND ASPHALT BASE, RECYCLE PAVEMENT AND MODIFY ELECTRICAL.
Location Description: MONO COUNTY NEAR TOM\\\\'S PLACE FROM 0.5 MILE NORTH OF LOWER ROCK CREEK ROAD TO 1.3 MILES SOUTH OF SOUTH LANDING OVERCROSSING
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: Unknown
Resident Engineer: David Carruba Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-05-21-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/21/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/21/2025
The quantity of what the sample constitutes: 1 box HMA
A brief description of the sample: 3/4” HMA
From where was the sample collected: Job Site
Laboratory sample identification: HMA 2
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Bishop

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 2

DIME Test ID: 2025-05-21-2-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/22/2025
Date Tested: 05/22/2025
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-2
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7310.5 grams
Mass of oven-dry sample in air for Sample 1 2163.7 grams
Mass of container filled with the sample and water for Sample 1 8594.1 grams
Temperature of Water 77.2 °F
Specific Gravity for Sample 1 2.458
Theoretical maximum density at 25°C (77°F) 153 lb/ft^3

Test 2 of 2

DIME Test ID: 2025-05-21-2-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/22/2025
Date Tested: 05/22/2025
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-2
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4245.8 g
Mass of the specimen and specimen basket assembly prior to ignition 6053.1 g
Mass of HMA Sample prior to ignition 1807.3 g
Corrected Asphalt Binder Content 4.35 %
Mass Loss 85.4 g
Mass of aggregate remaining after ignition 1721.9 g
Correction Factor (Percent by mass of HMA Specimen) 0.38 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C