Print Report | Back to Sample Detail

Sample Record for 2025-04-18-56

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000272 DEA: 100V4804 EFIS: 1013000264 QA Service Level: 1
DIST-CO-RTE-PM: 10-CAL-26-21.8/30.3
Work Description: SLOPE STABILIZATION AND CONSTRUCT RETAINING WALL.
Location Description: CALAVERAS COUNTY NEAR MOKELUMNE HILL AT VARIOUS LOCATIONS FROM 3.6 MILES EAST OF ROUTE 49 TO 0.9 MILE WEST OF WOODHOUSE MINE ROAD
Contractor Name: VIKING CONSTRUCTION COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: Jonathan Ngai Structure Rep.: Conor Hennessy

Sample Information

DIME Sample ID: 2025-04-18-56
TL Number from the TL Form:
Sample Submitted By Organization: Precast Unlimited Inc.
Sample Organization Contact: (530) 243-6477
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 04/18/2025
Date that the sample was received by the laboratory/organization performing the testing: 04/18/2025
The quantity of what the sample constitutes: 448.6g
A brief description of the sample: State Sand
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: JF Shea Construction, Shasta Redi-Mix, Redding, CA

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-45-0019
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant Stockpile
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: fine
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2025-04-18-56-1
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 05/21/2025
Date Tested: 04/18/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? Fine Aggregate
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 99 %
Cumulative percent passing the #8 sieve 77 %
Cumulative percent passing the #16 sieve 52 %
Cumulative percent passing the #30 sieve 29 %
Cumulative percent passing the #50 sieve 12 %
Cumulative percent passing the #100 sieve 5 %
Cumulative percent passing the #200 sieve 3.5 %

Test 2 of 3

DIME Test ID: 2025-04-18-56-2
Test Method: ASTM C117-17: Standard Test Method for Materials Finer than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 05/21/2025
Date Tested: 04/18/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent finer than No. 200 sieve 3.3 %

Test 3 of 3

DIME Test ID: 2025-04-18-56-3
Test Method: ASTM C566-19: Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying
Verified Date: 05/21/2025
Date Tested: 04/18/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total evaporable moisture content 7.2 %