Sample Record for 2025-05-08-66
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1000698 DEA: 024H0704 EFIS: 0218000074
QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS-139-0.74/11.0
Work Description: PLACE HMA (TYPE A), TRAFFIC CONTROL SYSTEM, TRAFFIC STRIPE, RDWY EXC.
Location Description: LASSEN COUNTY NEAR SUSANVILLE FROM 0.1 MILE NORTH OF CHESTNUT STREET TO 2.6 MILES SOUTH OF HORSE LAKE ROAD
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: Unknown
Resident Engineer: Daniel Gibbs Structure Rep.: Tooraj Yegan
Sample Information
DIME Sample ID: 2025-05-08-66
TL Number from the TL Form: 859030
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Aggregate
Sample Taken Date: 05/08/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/08/2025
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 2 bags of Combined Lime Treated 3/4-inch Virgin Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification: D79866
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction & Materials — Ward Lake Plant (Litchfield, CA)
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-18-0008::Ward Lake Pit (Litchfield, CA)
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Cold Feed
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number: 1
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 1
DIME Test ID: 2025-05-08-66-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 05/20/2025
Date Tested: 05/13/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
What type of gradation is being tested?
|
HMA Gradation
|
|
Cumulative percent passing the 2 in. sieve
|
no data
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
98 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
77 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
64 %
|
|
Cumulative percent passing the #4 sieve
|
36 %
|
|
Cumulative percent passing the #8 sieve
|
22 %
|
|
Cumulative percent passing the #16 sieve
|
14 %
|
|
Cumulative percent passing the #30 sieve
|
10 %
|
|
Cumulative percent passing the #50 sieve
|
7 %
|
|
Cumulative percent passing the #100 sieve
|
5 %
|
|
Cumulative percent passing the #200 sieve
|
4.1 %
|