Print Report | Back to Sample Detail

Sample Record for 2025-05-19-27

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993825 DEA: 040Q30U4 EFIS: 0420000235 COOP: 042830A3,042830A4 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA,CC-680-R11.0/R21.9,R0.0/R0.9
Work Description: PRECAST CONC PVMT, ELECTRONIC TOLL SYSTEM, JPCP, CB & STRUCTURAL CONC
Location Description: ALAMEDA AND CONTRA COSTA COUNTIES AT SUNOL AND IN SAN RAMON BETWEEN 0.4 MILE SOUTH OF CALAVERAS ROAD UNDERCROSSING TO 0.9 MILE NORTH OF ALCOSTA BOULEVARD OVERCROSSING
Contractor Name: BAY CITIES PAVING & GRADING (Jason Ochoa)
Contractor Address: 1450 CIVIC CT, BLDG B #400, CONCORD, CA 94520
Resident Engineer: Yannaing Tun Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-05-19-27
TL Number from the TL Form: C519251
Sample Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Sample Organization Contact: (510) 224-6127
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/19/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/19/2025
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 1/2"RHMA-O
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Pleasanton

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number: 1
Sublot number: 13
HMA Mix Number: 326114W
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2025-05-19-27-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/20/2025
Date Tested: 05/20/2025
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Lot 1 SL 13
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 2882.9 g
Mass of the specimen and specimen basket assembly prior to ignition 4426.6 g
Mass of HMA Sample prior to ignition 1543.7 g
Corrected Asphalt Binder Content 7.95 %
Mass Loss 129 g
Mass of aggregate remaining after ignition 1414.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.22 %
Moisture Content no data0 %
Temperature Compensation Factor 0.19 %
Test Temperature 482 C