Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995067 DEA: 11430394 EFIS: 1118000115
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-23.9/25.1
Work Description: WIDEN FREEWAY, STRUCTURES, CONSTRUCT SIGNS, LANDSCAPE AND ELECTRICAL.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.2 MILE NORTH OF ROUTE 805/52 SEPARATION TO 0.3 MILE SOUTH OF NOBEL DRIVE OVERCROSSING
Contractor Name: GRIFFITH COMPANY
Contractor Address: 13400 Sabre Spring Parkway Ste 200, San Diego, CA 92128
Resident Engineer: Tyler Jones Structure Rep.: Carlos Guzman
DIME Sample ID: 2025-05-12-39
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/12/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/16/2025
The quantity of what the sample constitutes: 2 boxes
A brief description of the sample: Plant Sample
From where was the sample collected: Manufacturer
Laboratory sample identification: 25-05-12-39-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta
DIME Test ID: 2025-05-12-39-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/16/2025
Date Tested: 05/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target - 7.5% Tested 7.63 %
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4009.7 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5577.4 g
|
|
Mass of HMA Sample prior to ignition
|
1567.7 g
|
|
Corrected Asphalt Binder Content
|
7.63 %
|
|
Mass Loss
|
125.9 g
|
|
Mass of aggregate remaining after ignition
|
1441.8 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.4 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2025-05-12-39-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/16/2025
Date Tested: 05/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target - 2.457
Tested 2.444
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1530.8 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8380 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.444
|
|
Theoretical maximum density at 25°C (77°F)
|
152.1 lb/ft^3
|