Print Report | Back to Sample Detail

Sample Record for 2025-05-12-39

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995067 DEA: 11430394 EFIS: 1118000115 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-23.9/25.1
Work Description: WIDEN FREEWAY, STRUCTURES, CONSTRUCT SIGNS, LANDSCAPE AND ELECTRICAL.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.2 MILE NORTH OF ROUTE 805/52 SEPARATION TO 0.3 MILE SOUTH OF NOBEL DRIVE OVERCROSSING
Contractor Name: GRIFFITH COMPANY
Contractor Address: 13400 Sabre Spring Parkway Ste 200, San Diego, CA 92128
Resident Engineer: Tyler Jones Structure Rep.: Carlos Guzman

Sample Information

DIME Sample ID: 2025-05-12-39
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/12/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/16/2025
The quantity of what the sample constitutes: 2 boxes
A brief description of the sample: Plant Sample
From where was the sample collected: Manufacturer
Laboratory sample identification: 25-05-12-39-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 21218080SR MM
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 2

DIME Test ID: 2025-05-12-39-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/16/2025
Date Tested: 05/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target - 7.5% Tested 7.63 %
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4009.7 g
Mass of the specimen and specimen basket assembly prior to ignition 5577.4 g
Mass of HMA Sample prior to ignition 1567.7 g
Corrected Asphalt Binder Content 7.63 %
Mass Loss 125.9 g
Mass of aggregate remaining after ignition 1441.8 g
Correction Factor (Percent by mass of HMA Specimen) 0.4 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2025-05-12-39-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/16/2025
Date Tested: 05/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target - 2.457 Tested 2.444
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 1530.8 grams
Mass of container filled with the sample and water for Sample 1 8380 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.444
Theoretical maximum density at 25°C (77°F) 152.1 lb/ft^3