Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000286 DEA: 070W7004 EFIS: 0723000032
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-405-44.7/48.64
Work Description: INDIVIDUAL SLAB REPLACEMENT (RSC), & GRIND EXIST CONC PAVEMENT.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES FROM NORDHOFF STREET UNDERCROSSING TO ROUTE 5/405 SEPARATION
Contractor Name: Interstate Civil Construction
Contractor Address: PO Box 2819, Wrightwood, CA 92397
Resident Engineer: ALI MOHSENZADEH Structure Rep.: Unknown
DIME Sample ID: 2025-03-24-95
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/24/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/14/2025
The quantity of what the sample constitutes: 8 BX RHMA 4 BG CMB AGG 4 QT RBR BLND 2 QT PG64-16 2 QT LAS 1 BG EA HN & CRM RBR
A brief description of the sample: 3/4" RHMA G SP 0.5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0291G-25
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Irwindale
DIME Test ID: 2025-03-24-95-1
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 06/02/2025
Date Tested: 05/17/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.321
|
DIME Test ID: 2025-03-24-95-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/02/2025
Date Tested: 05/16/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7349.1 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2658.8 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8908 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.417
|
|
Theoretical maximum density at 25°C (77°F)
|
2410 kg/m^3
|
DIME Test ID: 2025-03-24-95-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 06/02/2025
Date Tested: 05/17/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2025-03-24-95-4
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 06/02/2025
Date Tested: 05/20/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Average impression at 5000 passes (left/right avg)
|
2.28 mm
|
|
Average impression at 10000 passes (left/right avg)
|
2.91 mm
|
|
Average impression at 15000 passes (left/right avg)
|
3.54 mm
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|
DIME Test ID: 2025-03-24-95-5
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/02/2025
Date Tested: 05/16/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
2188 g
|
|
Corrected Asphalt Binder Content
|
7.22 %
|
|
Mass Loss
|
170.3 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.43 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
538 C
|