Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000007 DEA: 061F8304 EFIS: 0623000101
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-180-43.5/53.6
Work Description: COLD PLANE AC PAVEMENT, RHMA-G (BWC) AND HMA (TYPE A).
Location Description: FRESNO COUNTY NEAR KERMAN FROM GOLDENROD AVENUE TO BRAWLEY AVENUE
Contractor Name: CAL VALLEY CONSTRUCTION, INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2025-05-12-28
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/12/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/12/2025
The quantity of what the sample constitutes: 110 Tons
A brief description of the sample: 3/4 HMA
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: vulcan materials
DIME Test ID: 2025-05-12-28-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/15/2025
Date Tested: 05/14/2025
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
2894.3 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5105.6 g
|
|
Mass of HMA Sample prior to ignition
|
2211.3 g
|
|
Corrected Asphalt Binder Content
|
4.02 %
|
|
Mass Loss
|
97.2 g
|
|
Mass of aggregate remaining after ignition
|
2114.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.24 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
538 C
|