Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995085 DEA: 07322904 EFIS: 0716000059
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-27-0.0/18.6
Work Description: REMOVE EXISTING AC PAVEMENT & HMA OVERLAY.
Location Description: LOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET
Contractor Name: C. A. RASMUSSEN, INC.
Contractor Address: 28548 Livingston Ave, Valencia, CA 91355
Resident Engineer: Ravin Maru Structure Rep.: Unknown
DIME Sample ID: 2025-05-08-54
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/08/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/13/2025
The quantity of what the sample constitutes: 24 BX RHMA 4 QT PG64-16 4 QT RBR BLND 2 QT LAS 1 QT EXT OIL 1 CN HN 1 CN CRM RBR 4 BG CMB AG
A brief description of the sample: 1/2" RHMA G SP .5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0290G-25
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Sun Valley
DIME Test ID: 2025-05-08-54-1
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 06/02/2025
Date Tested: 05/19/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.378
|
DIME Test ID: 2025-05-08-54-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/02/2025
Date Tested: 05/17/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7349 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1560.3 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8265.2 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.422
|
|
Theoretical maximum density at 25°C (77°F)
|
2415 kg/m^3
|
DIME Test ID: 2025-05-08-54-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 06/02/2025
Date Tested: 05/19/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
DIME Test ID: 2025-05-08-54-4
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Verified Date: 06/02/2025
Date Tested: 06/02/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A)
|
15000
|
|
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B)
|
15000
|
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A)
|
5.54 mm
|
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B)
|
5 mm
|
|
Stripping Inflection Point (Wheel A)
|
10498
|
|
Stripping Inflection Point (Wheel B)
|
11266
|
DIME Test ID: 2025-05-08-54-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 06/02/2025
Date Tested: 05/21/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
132 psi
|
|
Average Wet Tensile Strength
|
87 psi
|
|
Tensile Strength Ratio
|
66.5
|
DIME Test ID: 2025-05-08-54-6
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/02/2025
Date Tested: 05/19/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1663.9 g
|
|
Corrected Asphalt Binder Content
|
7.3 %
|
|
Mass Loss
|
131.9 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.45 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.18 %
|
|
Test Temperature
|
538 C
|