Print Report | Back to Sample Detail

Sample Record for 2025-05-05-53

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995446 DEA: 060X0604 EFIS: 0618000015 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-198-0.5/19.5
Work Description: REMOVE AND REPLACE CULVERTS AND CURED IN PLACE PIPELINER.
Location Description: FRESNO COUNTY AT VARIOUS LOCATIONS FROM 1.3 MILES WEST OF WARTHAN CREEK OVERCROSSING TO 1.7 MILES WEST OF FIRESTONE AVENUE
Contractor Name: A. TEICHERT & SON, INC. DBA TEICHERT CONSTRUCTION
Contractor Address: 400 Sunrise Ave Ste 300,, Roseville, CA 95661
Resident Engineer: Tyler Street Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-05-05-53
TL Number from the TL Form:
Sample Submitted By Organization: Precast Unlimited Inc.
Sample Organization Contact: (530) 243-6477
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 05/05/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/05/2025
The quantity of what the sample constitutes: 9 4x8 Cylinders
A brief description of the sample: Concrete Test Samples
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Precast Unlimited Inc.

Material Information

The concrete mix design number: CT675SL
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 101463
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 5

DIME Test ID: 2025-05-05-53-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 05/13/2025
Date Tested: 05/05/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 73 F

Test 2 of 5

DIME Test ID: 2025-05-05-53-2
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 05/13/2025
Date Tested: 05/05/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample TC050525
Volume of the measure 0.25 ft^3
Density of concrete 146.2 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content no data

Test 3 of 5

DIME Test ID: 2025-05-05-53-3
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 05/13/2025
Date Tested: 05/05/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 7.25 inch

Test 4 of 5

DIME Test ID: 2025-05-05-53-4
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 05/13/2025
Date Tested: 05/05/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Air content 1.7 %

Test 5 of 5

DIME Test ID: 2025-05-05-53-5
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/02/2025
Date Tested: 06/02/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 8.5 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.56 in^2
Cross sectional area of cylinder 2 12.56 in^2
Cross sectional area of cylinder 3 12.56 in^2
Compressive strength (to nearest 10 psi) 5170 psi
Maximum load on cylinder 1 67140 lb
Maximum load on cylinder 2 63400 lb
Maximum load on cylinder 3 64370 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data