Print Report | Back to Sample Detail

Sample Record for 2025-05-07-38

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994875 DEA: 101F1804 EFIS: 1016000077 QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-4-R16.0/R19.4
Work Description: BRIDGE WORK, CONCRETE BARRIER, AND INSTALL RAMP METER SYSTEM.
Location Description: SAN JOAQUIN COUNTY IN STOCKTON AT VARIOUS LOCATIONS FROM 0.3 MILE EAST OF ROUTE 4/5 SEPARATION TO 0.4 MILE WEST OF ROUTE 4/99 SEPARATION
Contractor Name: VIKING CONSTRUCTION COMPANY, INC.
Contractor Address: P.O. Box 1508, Rancho Cordova, CA 95741
Resident Engineer: Toafael Anwar Structure Rep.: Ron Matin

Sample Information

DIME Sample ID: 2025-05-07-38
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 05/07/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/09/2025
The quantity of what the sample constitutes: 4
A brief description of the sample: Lenton Couplers
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Field

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: CMC
Coupler Manufacturer: Erico
Intermediate Assembler or Fabricator:
Rebar Size: #11
Coupler Model: Lenton
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): M0268
Rebar Heat Number(s): 9005572
Rebar Size 2 :
Coupler Unique ID: ST-17-01

Test Results

Test 1 of 1

DIME Test ID: 2025-05-07-38-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 05/28/2025
Date Tested: 05/28/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 4
SampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11111.560.005915206097474ok neckingAtlas
21111.56000015256097795ok neckingAtlas
31111.56000014832095077ok neckingAtlas
41111.56000015045096442ok neckingAtlas
Temperature 0 f
UTM NA
Halo ID na