Sample Record for 2025-05-06-7
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 215365 DEA: 120Q9704 EFIS: 1218000010
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-405-0/11.4
Work Description: I-405 improvement project from I-5 to Harbor Boulevard including extend pavement life, improve safety, enhance traffic operation, and incorporate Intelligent Transportation Systems (ITS).
Location Description: Orange County I-405 PM 0 - 11.4
Contractor Name: Guy F. Atkinson
Contractor Address: 38 Executive Park, IRVINE CA 92614
Resident Engineer: Mona Shahidi Structure Rep.: Brian Vo
Sample Information
DIME Sample ID: 2025-05-06-7
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/06/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/12/2025
The quantity of what the sample constitutes: 10
A brief description of the sample: 1 1/4" x 20"
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Halo Structural Products
Material Information
Rocap Number(s):
Heat Number(s): 20975430,8000031330, 236822
Nut Mfg. Lot Number(s): W000206516
Washer Mfg. Lot Number(s): 236822 / 40618
Bolt Specification: ASTM F1554
Bolt Length(s): 20"
Nut Specification: ASTM A563
Washer Specification: ASTM F436
Finish: ASTM F2329
Diameter/Size: 1 1/4"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
Test Results
Test 1 of 8
DIME Test ID: 2025-05-06-7-1
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 05/21/2025
Date Tested: 05/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
20975430
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
YELLOW
|
|
Size
|
1.25 in
|
|
Bolt Length
|
20 in
|
|
Gage Type
|
Pass
|
Test 2 of 8
DIME Test ID: 2025-05-06-7-2
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 05/21/2025
Date Tested: 05/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
W000206516
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
DH N
|
|
Size
|
1.25 in
|
|
Gage Type
|
Pass
|
Test 3 of 8
DIME Test ID: 2025-05-06-7-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
20975430
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.25 in
|
|
Bolt Length
|
20 in
|
|
Measurement Average
|
10.9 mils
|
Test 4 of 8
DIME Test ID: 2025-05-06-7-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
W000206516
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.25 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
4.7 mils
|
Test 5 of 8
DIME Test ID: 2025-05-06-7-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
236822
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.25 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.2 mils
|
Test 6 of 8
DIME Test ID: 2025-05-06-7-6
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
W000206516
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.25 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
29
|
|
Spacing
|
Ok
|
Test 7 of 8
DIME Test ID: 2025-05-06-7-7
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
236822
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
1.25 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
35
|
|
Spacing
|
Ok
|
Test 8 of 8
DIME Test ID: 2025-05-06-7-8
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 05/21/2025
Date Tested: 05/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | 20975430 | 1.25 | 91560 | 0000 | 0 | yield 71150 | Kleinfelder |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|