Print Report | Back to Sample Detail

Sample Record for 2025-04-18-48

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994121 DEA: 120P68U4 EFIS: 1218000105 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-1-13.0/33.7
Work Description: COLD PLANE, PLACE RHMA AND MODIFY CURB RAMPS AND ELECTRICAL SYSTEMS.
Location Description: ORANGE COUNTY AT VARIOUS LOCATIONS FROM CRYSTAL HEIGHTS DRIVE TO LOS ANGELES/ORANGE COUNTY LINE
Contractor Name: CHUMO CONSTRUCTION INC.
Contractor Address: 4949 2nd St., Fallbrook, CA 92028
Resident Engineer: Christopher Blanco Structure Rep.: Vian Ghazi

Sample Information

DIME Sample ID: 2025-04-18-48
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 04/18/2025
Date that the sample was received by the laboratory/organization performing the testing: 04/25/2025
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American-Corona

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2025-04-18-48-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 05/13/2025
Date Tested: 04/29/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 63 C
Softening Point Sample 2 63 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2025-04-18-48-2
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 05/13/2025
Date Tested: 04/29/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 31 0.1 mm

Test 3 of 3

DIME Test ID: 2025-04-18-48-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 05/13/2025
Date Tested: 04/30/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 1 mm
Final Dial reading (F1) 59 mm
Ball Penetration (P2) 1 mm
Final Dial reading (F2) 58 mm
Ball Penetration (P3) 1 mm
Final Dial reading (F3) 60 mm
Resilience 1 42 %
Resilience 2 43 %
Resilience 3 41 %
Average Resilience 42 %
Minutes Reaction no data