Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001178 DEA: 020J3904 EFIS: 0219000112
QA Service Level: 2
DIST-CO-RTE-PM: 02---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Nathan Alexander Structure Rep.: Unknown
DIME Sample ID: 2025-04-22-50
TL Number from the TL Form: 823625
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 04/22/2025
Date that the sample was received by the laboratory/organization performing the testing: 04/23/2025
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 1 bag of Combined RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: D79859B
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: J.F. Shea Construction — Fawndale Rock and Asphalt (Redding, CA)
RAP Source: Fawndale Rock and Asphalt, Redding, CA
Aggregate Size: 3/8-inch
Aggregate Source:
RAP Stockpile:
Stockpile Size (tons):
Reclaimed Asphalt Pavement Mix Number:
DIME Test ID: 2025-04-22-50-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/29/2025
Date Tested: 04/24/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmmr=2.590
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7332.2 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1619.1 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8326.1 grams
|
|
Temperature of Water
|
76 °F
|
|
Specific Gravity for Sample 1
|
2.59
|
|
Theoretical maximum density at 25°C (77°F)
|
2582.5 kg/m^3
|
DIME Test ID: 2025-04-22-50-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/29/2025
Date Tested: 04/24/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pbr(uncorrected)=6.09
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3029.9 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4645.2 g
|
|
Mass of HMA Sample prior to ignition
|
1615.3 g
|
|
Corrected Asphalt Binder Content
|
6.09 %
|
|
Mass Loss
|
101.4 g
|
|
Mass of aggregate remaining after ignition
|
1513.9 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.19 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2025-04-22-50-3
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 04/29/2025
Date Tested: 04/29/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
Yes
|
|
Aggregate correction factor for the 2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 1/2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 3/4 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1/2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 3/8 in. sieve (% passing)
|
-1.3 %
|
|
Aggregate correction factor for the #4 sieve (% passing)
|
2 %
|
|
Aggregate correction factor for the #8 sieve (% passing)
|
1.3 %
|
|
Aggregate correction factor for the #16 sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the #30 sieve (% passing)
|
-0.7 %
|
|
Aggregate correction factor for the #50 sieve (% passing)
|
-2.7 %
|
|
Aggregate correction factor for the #100 sieve (% passing)
|
-3 %
|
|
Aggregate correction factor for the #200 sieve (% passing)
|
-2.9 %
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
98 %
|
|
Cumulative percent passing the #4 sieve
|
81 %
|
|
Cumulative percent passing the #8 sieve
|
58 %
|
|
Cumulative percent passing the #16 sieve
|
40 %
|
|
Cumulative percent passing the #30 sieve
|
28 %
|
|
Cumulative percent passing the #50 sieve
|
19 %
|
|
Cumulative percent passing the #100 sieve
|
13 %
|
|
Cumulative percent passing the #200 sieve
|
9.9 %
|