Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 210687 DEA: 07316604
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-1-41.8/42.1, 41.8-42.1
Work Description: INSTALL RSP TO PREVENT HIGH SURF FROM DESTROYING ROADWAY SUPPORT SLOPE, TRAVEL WAY
Location Description: IN LA,IN MALIBU 1MILE N/O TOPANGE CNY RD
Contractor Name: NORDIC INDUSTRIES, INC.
Contractor Address: 1437 FURNEAUX ROAD , OLIVEHURST, CA 95961
Resident Engineer: Gilbert Trujillo Structure Rep.: Unknown
DIME Sample ID: 2025-04-18-37
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/18/2025
Date that the sample was received by the laboratory/organization performing the testing: 03/07/2025
The quantity of what the sample constitutes: 50 CY
A brief description of the sample: 6 x 12 JPCP Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 25-0757
Structure unique identifier:
Structure name: SR-14 NB Technology to Avenue N Stations:3275+80
The fabricator/manufacturer/facility name: N/A
The concrete mix design number: SCI-12622-1
The truck number from where the sample was collected: Ticket or Truck 5
The batch plant ticket number from where the sample was collected: LOAD 5
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Jobsite
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2025-04-18-37-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/25/2025
Date Tested: 04/18/2025
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
5.94 in
|
|
Average diameter of cylinder 2
|
5.95 in
|
|
Average diameter of cylinder 3
|
5.95 in
|
|
Cross sectional area of cylinder 1
|
27.71 in^2
|
|
Cross sectional area of cylinder 2
|
27.81 in^2
|
|
Cross sectional area of cylinder 3
|
27.81 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5710 psi
|
|
Maximum load on cylinder 1
|
160739 lb
|
|
Maximum load on cylinder 2
|
156814 lb
|
|
Maximum load on cylinder 3
|
158649 lb
|
|
Compressive strength of cylinder 1
|
5800.8 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
5638.8 psi
|
|
Compressive strength of cylinder 3
|
5704.7 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
42 days
|
|
Age of specimen in hours
|
no data0 hours
|