Sample Record for 2025-04-01-26
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994539 DEA: 021H58U4 EFIS: 0223000059
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-70-58.2/R78.4
Work Description: RECONSTRUCT ROADWAY, HMA PAVING, DRAINAGE AND ELECTRICAL WORK.
Location Description: PLUMAS COUNTY AT AND NEAR CROMBERG FROM GILL RANCH ROAD TO 0.2 MILE WEST OF BIG GRIZZLY CREEK BRIDGE
Contractor Name: MERCER-FRASER COMPANY
Contractor Address: PO Box 1006, Eureka, CA 95502
Resident Engineer: Mike Zdenek Structure Rep.: Brandon Thurber
Sample Information
DIME Sample ID: 2025-04-01-26
TL Number from the TL Form:
Sample Submitted By Organization: Precast Unlimited Inc.
Sample Organization Contact: (530) 243-6477
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 04/01/2025
Date that the sample was received by the laboratory/organization performing the testing: 04/01/2025
The quantity of what the sample constitutes: 538.8g
A brief description of the sample: Sand
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Shasta Ready Mix
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-45-0019
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Shasta Ready Mix Stockpile
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: fine
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 3
DIME Test ID: 2025-04-01-26-1
Test Method: ASTM C117-17: Standard Test Method for Materials Finer than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 04/25/2025
Date Tested: 04/01/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Percent finer than No. 200 sieve
|
3.9 %
|
Test 2 of 3
DIME Test ID: 2025-04-01-26-2
Test Method: ASTM C566-19: Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying
Verified Date: 04/25/2025
Date Tested: 04/01/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Total evaporable moisture content
|
10.6 %
|
Test 3 of 3
DIME Test ID: 2025-04-01-26-3
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 04/25/2025
Date Tested: 04/01/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
What type of gradation is being tested?
|
Fine Aggregate
|
|
Cumulative percent passing the 3/8 in. sieve
|
100 %
|
|
Cumulative percent passing the #4 sieve
|
99 %
|
|
Cumulative percent passing the #8 sieve
|
79 %
|
|
Cumulative percent passing the #16 sieve
|
56 %
|
|
Cumulative percent passing the #30 sieve
|
32 %
|
|
Cumulative percent passing the #50 sieve
|
15 %
|
|
Cumulative percent passing the #100 sieve
|
8 %
|
|
Cumulative percent passing the #200 sieve
|
6 %
|