Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000416 DEA: 120S1104 EFIS: 1219000091
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-22-R0.9/R9.4
Work Description: REPLACE CONCRETE BARRIER AND MODIFY LIGHTING SYSTEM.
Location Description: ORANGE FROM BOLSA CHICA ROAD OVERCROSSING IN GARDEN GROVE TO LEWIS STREET OVERCROSSING IN ORANGE
Contractor Name: BEADOR CONSTRUCTION COMPANY, INC.
Contractor Address: 2900 Bristol Street Suite D204, Costa Mesa, CA 92626
Resident Engineer: Arezo Ghiam Structure Rep.: Maheshwarlal Kapoor
DIME Sample ID: 2025-04-17-47
TL Number from the TL Form:
Sample Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Sample Organization Contact: 9492798846
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/17/2025
Date that the sample was received by the laboratory/organization performing the testing: 04/18/2025
The quantity of what the sample constitutes: 6
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 25-0134
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: National / Artesia
The concrete mix design number: S59C456T10
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 182201
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Dischard fron concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled: Knott Ave. UC Br. 55-0366 90+63~92+71
From Lot No.:
Bag Lot No.:
DIME Test ID: 2025-04-17-47-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/24/2025
Date Tested: 04/24/2025
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
3.99 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
3.97 in
|
|
Cross sectional area of cylinder 1
|
12.5 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.38 in^2
|
|
Compressive strength (to nearest 10 psi)
|
2890 psi
|
|
Maximum load on cylinder 1
|
35610 lb
|
|
Maximum load on cylinder 2
|
36240 lb
|
|
Maximum load on cylinder 3
|
36530 lb
|
|
Compressive strength of cylinder 1
|
2848.8 psi
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Compressive strength of cylinder 2
|
2883.1 psi
|
|
Compressive strength of cylinder 3
|
2950.7 psi
|
|
Type of fracture pattern of cylinder 2
|
5
|
|
Type of fracture pattern of cylinder 3
|
5
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|
DIME Test ID: 2025-04-17-47-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/29/2025
Date Tested: 05/29/2025
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
3.99 in
|
|
Average diameter of cylinder 2
|
3.99 in
|
|
Average diameter of cylinder 3
|
3.98 in
|
|
Cross sectional area of cylinder 1
|
12.5 in^2
|
|
Cross sectional area of cylinder 2
|
12.5 in^2
|
|
Cross sectional area of cylinder 3
|
12.44 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4860 psi
|
|
Maximum load on cylinder 1
|
59740 lb
|
|
Maximum load on cylinder 2
|
63170 lb
|
|
Maximum load on cylinder 3
|
58910 lb
|
|
Compressive strength of cylinder 1
|
4779.2 psi
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Compressive strength of cylinder 2
|
5053.6 psi
|
|
Compressive strength of cylinder 3
|
4735.5 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
42 days
|
|
Age of specimen in hours
|
no data0 hours
|