Print Report | Back to Sample Detail

Sample Record for 2025-04-16-43

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000189 DEA: 112N1714 EFIS: 1122000284 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-0.5/14.6
Work Description: METHACRYLATE REPLACE APPROACH SLABS, JOINT SEALS AND CONCRETE OVERLAY.
Location Description: SAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM SOUTH ROUTE 805/5 SEPARATION TO ROUTE 805/15 SEPARATION
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION, INC.
Contractor Address: 16351 CONSTRUCTION CIR W, IRVINE CA 92606
Resident Engineer: John Tran Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-04-16-43
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 04/16/2025
Date that the sample was received by the laboratory/organization performing the testing: 04/17/2025
The quantity of what the sample constitutes: 17 totes
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000157KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia

Material Information

Mfg. Lot Number(s): ET5D00490
Batch number: ET5D00490
Mix number: ET5D00490

Test Results

Test 1 of 6

DIME Test ID: 2025-04-16-43-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 06/18/2025
Date Tested: 06/17/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity 95

Test 2 of 6

DIME Test ID: 2025-04-16-43-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 06/18/2025
Date Tested: 06/17/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 9

Test 3 of 6

DIME Test ID: 2025-04-16-43-3
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 06/18/2025
Date Tested: 06/17/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 46

Test 4 of 6

DIME Test ID: 2025-04-16-43-4
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 06/18/2025
Date Tested: 06/12/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 6
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.516 in
Sample 1 Ultimate strength 2619.2 psi
Sample 1 Thickness 0.256 in
Sample 1 Area 0.1321 in^2
Sample 1 Ultimate Strength Actual 346 lbs
Sample 1 percent elongation 56 %
Sample 1 Time no data0 MM:SS
Sample 2 Width 0.516 in
Sample 2 Thickness 0.251 in
Sample 2 Area 0.1295 in^2
Sample 2 Ultimate strength 2656.4 psi
Sample 2 Ultimate Strength Actual 344 lbs
Sample 2 percent elongation 54 %
Sample 2 Time no data0 MM:SS
Sample 3 Width 0.513 in
Sample 3 Thickness 0.256 in
Sample 3 Area 0.1313 in^2
Sample 3 Ultimate strength 2597.1 psi
Sample 3 Ultimate Strength Actual 341 lbs
Sample 3 percent elongation 54 %
Sample 3 Time no data0 MM:SS
Sample 4 Width 0.513 in
Sample 4 Thickness 0.239 in
Sample 4 Area 0.1226 in^2
Sample 4 Ultimate strength 2805.9 psi
Sample 4 Ultimate Strength Actual 344 lbs
Sample 4 percent elongation 58 %
Sample 4 Time no data0 MM:SS
Sample 5 Width 0.518 in
Sample 5 Thickness 0.246 in
Sample 5 Area 0.1274 in^2
Sample 5 Ultimate strength 2770.8 psi
Sample 5 Ultimate Strength Actual 353 lbs
Sample 5 percent elongation 56 %
Sample 5 Time no data0 MM:SS
Sample 6 Width 0.513 in
Sample 6 Thickness 0.26 in
Sample 6 Area 0.1334 in^2
Sample 6 Ultimate strength 2548.7 psi
Sample 6 Ultimate Strength Actual 340 lbs
Sample 6 percent elongation 56 %
Sample 6 Time no data0 MM:SS
Ultimate Strength Average 2666 psi
Percent Elongation Average 56 %

Test 5 of 6

DIME Test ID: 2025-04-16-43-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 06/18/2025
Date Tested: 04/23/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test: Accepted supplier's result.
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1 24hr
Maximum applied load (P) for Sample 1 1460 lb
Span length for Sample 1 9 in
Break location for Sample 1 bond
Specimen defects/notes for Sample 1 no data
Surface type for Sample 1 SSD
Modulus of rupture (R) for Sample 1 730 psi
Curing history for Sample 2 24hr
Maximum applied load (P) for Sample 2 1446 lb
Span length for Sample 2 9 in
Break location for Sample 2 bond
Specimen defects/notes for Sample 2 no data
Surface type for Sample 2 SSD
Modulus of rupture (R) for Sample 2 723 psi
Curing history for Sample 3 24hr
Maximum applied load (P) for Sample 3 1704 lb
Span length for Sample 3 9 in
Break location for Sample 3 bond
Specimen defects/notes for Sample 3 no data
Surface type for Sample 3 SSD
Modulus of rupture (R) for Sample 3 852 psi

Test 6 of 6

DIME Test ID: 2025-04-16-43-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 06/18/2025
Date Tested: 06/17/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 154 mm
Room Temperature 74 f
Tare weight no data
Initial weight 100.1 grams
Weight at 5 minutes 99.96 grams
Weight at 10 minutes 99.83 grams
Weight at 15 minutes 99.7 grams
Weight at 20 minutes 99.57 grams
Weight at 25 minutes 99.44 grams
Weight at 30 minutes 99.32 grams
Final weight 99.32 grams
Total weight loss 0.78 grams
Calculated radius of gallon can lid in cm 7.7 cm
Lid Factor 53.687 m^2
Volatile emission 41.876 grams/m^2