Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2025-04-14-48
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/14/2025
Date that the sample was received by the laboratory/organization performing the testing: 05/01/2025
The quantity of what the sample constitutes: 54
A brief description of the sample: Anchor Bolts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales, Inc.
Rocap Number(s): na
Heat Number(s): 1201064394
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): na
Bolt Specification: F1554-55 S1
Bolt Length(s): 40"
Nut Specification: na
Washer Specification: na
Finish: Plain/Hot Dip Galvanize
Diameter/Size: 2-1/2"
Bolt Mfg. Lot Number: see Heat # 1201064394
Rocap Test Requirement(s): na
Lubricant Requirements(s): na
Washer Inner Diameter(s):
DIME Test ID: 2025-04-14-48-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/05/2025
Date Tested: 06/03/2025
Submitted By Organization: Atlas - Oakland
Organization Address: 534 23rd Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94606
Organization Email: guillermo.baltazar@oneatlas.com
Organization Phone: (510) 434-3018
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1202064394
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain and A153 and F2329
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
7.3 mils
|
DIME Test ID: 2025-04-14-48-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/05/2025
Date Tested: 06/03/2025
Submitted By Organization: Atlas - Oakland
Organization Address: 534 23rd Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94606
Organization Email: guillermo.baltazar@oneatlas.com
Organization Phone: (510) 434-3018
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1202064394
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain and A153 and F2329
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
6.1 mils
|
DIME Test ID: 2025-04-14-48-5
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/05/2025
Date Tested: 06/03/2025
Submitted By Organization: Atlas - Oakland
Organization Address: 534 23rd Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94606
Organization Email: guillermo.baltazar@oneatlas.com
Organization Phone: (510) 434-3018
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1202064394
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain and A153 and F2329
|
|
Product Markings
|
YELLOW
|
|
Size
|
2.5 in
|
|
Bolt Length
|
40 in
|
|
Pitch Diameter
|
2.3469 in
|
|
Pitch Diameter 2nd
|
2.3469 in
|
DIME Test ID: 2025-04-14-48-6
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/05/2025
Date Tested: 06/03/2025
Submitted By Organization: Atlas - Oakland
Organization Address: 534 23rd Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94606
Organization Email: guillermo.baltazar@oneatlas.com
Organization Phone: (510) 434-3018
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1202064394
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain and A153 and F2329
|
|
Product Markings
|
YELLOW
|
|
Size
|
2.5 in
|
|
Bolt Length
|
40 in
|
|
Pitch Diameter
|
2.3484 in
|
|
Pitch Diameter 2nd
|
2.3484 in
|
DIME Test ID: 2025-04-14-48-7
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 06/05/2025
Date Tested: 06/03/2025
Submitted By Organization: Atlas - Oakland
Organization Address: 534 23rd Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94606
Organization Email: guillermo.baltazar@oneatlas.com
Organization Phone: (510) 434-3018
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
2
|
| Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | 1A | 1202064394 | 2.50 | 4.00 | 58080 | 82070 | 0 | W Torres | | 1B | 1202064394 | 2.50 | 4.00 | 58165 | 84925 | 0 | W Torres |
| |
|
UTM
|
NA
|
|
Temperature
|
72 f
|