Print Report | Back to Sample Detail

Sample Record for 2025-04-16-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000216 DEA: 081G6304 EFIS: 0816000043 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-111-47.2/55.3
Work Description: RHMA-G, REPLACE AC SURFACING, AND COLD PLANE AC PVMT.
Location Description: RIVERSIDE COUNTY IN PALM SPRINGS FROM GOLF CLUB DRIVE TO WEST GATEWAY DRIVE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 3800 Monroe St, Indio Ca 92203
Resident Engineer: Francisco Montellano Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-04-16-7
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/16/2025
Date that the sample was received by the laboratory/organization performing the testing: 04/17/2025
The quantity of what the sample constitutes: 2 BOXES OF RHMA, 2 QTS PG64-16, 2 QTS RUBBER BLEND, 1 QT EVO, 1 QT RAFFEX
A brief description of the sample: 3/4" RHMA G SP .50% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0224G-25
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Desert Hot Springs

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 1556
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2025-04-16-7-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/24/2025
Date Tested: 04/18/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2164.6 g
Corrected Asphalt Binder Content 7.99 %
Mass Loss 175.2 g
Correction Factor (Percent by mass of HMA Specimen) -0.04 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C