Project ID: 1000073 DEA: 120N3704 EFIS: 1214000005 COOP: 12820
QA Service Level: 2
DIST-CO-RTE-PM: 12-ORA-I-5-R25.0
Work Description: Construct Class I bicycle and pedestrian bridge/trail connection of the Jeffrey Open Space Trail (JOST) across I-5.
Location Description: I-5/Jeffrey Road Interchange
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Nader Naderi Structure Rep.: Nader Naderi
DIME Sample ID: 2024-12-20-42
TL Number from the TL Form:
Sample Submitted By Organization: Sequoia Consultants
Sample Organization Contact: (714) 974-6316
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 12/20/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/21/2024
The quantity of what the sample constitutes: 2 cylinders
A brief description of the sample: structural concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Holliday Rock Irvine
The concrete mix design number: 3G60H000
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 108198772
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Frame 1 Stem & Soffit
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-12-20-42-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/14/2025
Date Tested: 01/17/2025
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
6.00 in
|
|
Average diameter of cylinder 2
|
6.00 in
|
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
|
Compressive strength (to nearest 10 psi)
|
7860 psi
|
|
Maximum load on cylinder 1
|
223640 lb
|
|
Maximum load on cylinder 2
|
220560 lb
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|