Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995482 DEA: 112T36U4 EFIS: 1122000243
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-37.4-52.6
Work Description: I-5 NCC SEGMENT 4C
Location Description: I-5 in San Diego County at Various Locations from Lomas Santa Fe Drive Undercrossing to 0.2 Mile North of Oceanside Undercrossing
Contractor Name: Flatiron-Skanska-Stacy and Witbeck Joint Venture
Contractor Address: 1770 La Costa Meadows Drive, San Marcos, CA 92078
Resident Engineer: Yong Pak Structure Rep.: Phong Le
DIME Sample ID: 2025-04-09-11
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/09/2025
Date that the sample was received by the laboratory/organization performing the testing: 04/11/2025
The quantity of what the sample constitutes: 16 boxes
A brief description of the sample: PSU
From where was the sample collected: Supplier
Laboratory sample identification: 25-04-09-11 PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta
DIME Test ID: 2025-04-09-11-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/17/2025
Date Tested: 04/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 7.5% Save Material for T30
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4013.9 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5586.1 g
|
|
Mass of HMA Sample prior to ignition
|
1572.2 g
|
|
Corrected Asphalt Binder Content
|
7.54 %
|
|
Mass Loss
|
124.8 g
|
|
Mass of aggregate remaining after ignition
|
1447.4 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.4 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2025-04-09-11-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/17/2025
Date Tested: 04/17/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Does not Comply Target = 2.457 Tested 2 times 1st- 2.423 and 2nd- 2.425
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1545.2 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8383.6 grams
|
|
Temperature of Water
|
no data0 °F
|
|
Specific Gravity for Sample 1
|
2.425
|
|
Theoretical maximum density at 25°C (77°F)
|
150.9 lb/ft^3
|
DIME Test ID: 2025-04-09-11-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 04/17/2025
Date Tested: 04/17/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Tested Ave 3.0% Avg Height 118.1
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.355
|
|
Bulk Specific Gravity 2
|
2.35
|
|
Bulk Specific Gravity 3
|
2.353
|
|
Average Bulk Specific Gravity
|
2.353
|
DIME Test ID: 2025-04-09-11-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 04/17/2025
Date Tested: 04/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Tested Avg of 3.0% and Avg Height of 118.1 mm
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
2.9 %
|
|
Percent Air Voids 2
|
3.1 %
|
|
Percent Air Voids 3
|
3 %
|
|
Average Percent Air Voids
|
3 %
|
DIME Test ID: 2025-04-09-11-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 04/25/2025
Date Tested: 04/25/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Does Not Comply Target - WET > 70 and DRY > 100
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
92 psi
|
|
Average Wet Tensile Strength
|
60 psi
|
|
Tensile Strength Ratio
|
0.65
|
DIME Test ID: 2025-04-09-11-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 04/30/2025
Date Tested: 04/29/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target < 12.7 mm Tested an Avg of 10.00 mm
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>20000
|
|
Stripping Inflection Point (Wheel B)
|
>20000
|
|
Maximum impression at 5000 passes (left wheel)
|
2.51 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
2.41 mm
|
|
Average impression at 5000 passes (left/right avg)
|
2.46 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
5.3 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
4.73 mm
|
|
Average impression at 10000 passes (left/right avg)
|
5.02 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
7.79 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
7.11 mm
|
|
Average impression at 15000 passes (left/right avg)
|
7.45 mm
|
|
Maximum impression at 20000 passes (left wheel)
|
10.59 mm
|
|
Maximum impression at 20000 passes (right wheel)
|
9.41 mm
|
|
Average impression at 20000 passes (left/right avg)
|
10 mm
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|