Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000580 DEA: 071XW104 EFIS: 0723000028
QA Service Level: 1
DIST-CO-RTE-PM: 07---
Work Description: VENTURA COUNTY IN CITY OF FILLMORE VEN-126REPLACE/CONSTRUCT THE FILLMORE MAINTENANCESTATION DAMAGED BY HIGH WINDS DIR\\'S EMERGENCY
Location Description:
Contractor Name: MGP CONSTRUCTION DBA MICHAEL
Contractor Address: PO BOX 355, UPLAND, CA 91785
Resident Engineer: ALFRED IRA Structure Rep.: Heidi Bernstein
DIME Sample ID: 2025-04-11-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/11/2025
Date that the sample was received by the laboratory/organization performing the testing: 04/17/2025
The quantity of what the sample constitutes: 2 of 48
A brief description of the sample: F1554 Grade 55 HDG Anchor Bolts
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Circle Corp
Rocap Number(s): N/A
Heat Number(s): 1201061488
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: F1554
Bolt Length(s): 18" - 38"
Nut Specification: N/A
Washer Specification: N/A
Finish: ASTM F2329
Diameter/Size: 3/4
Bolt Mfg. Lot Number: 18 inch lot 99285-1 ; 36 inch lot 99285-2
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
DIME Test ID: 2025-04-11-3-1
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 05/08/2025
Date Tested: 04/18/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1201061488
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
YELLOW
|
|
Size
|
0.75 in
|
|
Bolt Length
|
18 in
|
|
Gage Type
|
Pass
|
DIME Test ID: 2025-04-11-3-2
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 05/08/2025
Date Tested: 04/18/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
2A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1201061488
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
YELLOW
|
|
Size
|
0.75 in
|
|
Bolt Length
|
38 in
|
|
Gage Type
|
Pass
|
DIME Test ID: 2025-04-11-3-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2025
Date Tested: 05/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Tested by Kleinfelder Lab
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
0
|
|
Size
|
0.75 in
|
|
Bolt Length
|
18 in
|
|
Measurement Average
|
4.8 mils
|
DIME Test ID: 2025-04-11-3-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2025
Date Tested: 05/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Tested by Kleinfelder Lab
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
2a
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
0
|
|
Size
|
0.75
|
|
Bolt Length
|
38
|
|
Measurement Average
|
4.9
|
DIME Test ID: 2025-04-11-3-5
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 05/08/2025
Date Tested: 05/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Tested by Kleinfelder Lab
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
1
|
| Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | | 1 | 0.75 x38" | 0.334 | 29070 | 129 | 87036 | 64611 | 21580 | lot 99285-2 |
| |
|
UTM
|
NA
|
|
Temperature
|
72
|
DIME Test ID: 2025-04-11-3-6
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Tensile, Yield and Elongation)
Verified Date: 05/08/2025
Date Tested: 05/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Test by Kleinfelder Lab
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
1
|
| Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | 1201061488 99285-1 | 0.5 | 0.196 | 70436 | 90095 | 29 | M Kalwasinski Kleinfelder Lab |
| |
|
UTM
|
NA
|
|
Temperature
|
72 f
|