Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994947 DEA: 112T3644 EFIS: 1121000108
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-56-0.3/3.0
Work Description: CONSTRUCT JPCP, HMA, RHMA-G, SIGNS, BARRIERS, LANDSCAPE, & ELECTRICAL.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM EL CAMINO REAL UNDERCROSSING TO 0.3 MILE WEST OF CARMEL VALLEY ROAD OVERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real #200, Carlsbad, CA 92008
Resident Engineer: Steve Mcmillan Structure Rep.: Unknown
DIME Sample ID: 2025-04-06-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/06/2025
Date that the sample was received by the laboratory/organization performing the testing: 04/07/2025
The quantity of what the sample constitutes: 12 boxes
A brief description of the sample: PSUE
From where was the sample collected: Source
Laboratory sample identification: 25-04-06-2 PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta
DIME Test ID: 2025-04-06-2-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/08/2025
Date Tested: 04/08/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Does Not Comply Target 4.3% Tested 3 Times in 2 different ovens All Failed
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3959.1 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6018 g
|
|
Mass of HMA Sample prior to ignition
|
2058.9 g
|
|
Corrected Asphalt Binder Content
|
4.88 %
|
|
Mass Loss
|
104 g
|
|
Mass of aggregate remaining after ignition
|
1954.9 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.17 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2025-04-06-2-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/08/2025
Date Tested: 04/08/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 2.510 Tested 2.505
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2542.2 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
9002.8 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.505
|
|
Theoretical maximum density at 25°C (77°F)
|
155.9 lb/ft^3
|
DIME Test ID: 2025-04-06-2-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 04/08/2025
Date Tested: 04/08/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Tested 3.5% avg
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.417
|
|
Bulk Specific Gravity 2
|
2.417
|
|
Bulk Specific Gravity 3
|
2.416
|
|
Average Bulk Specific Gravity
|
2.417
|
DIME Test ID: 2025-04-06-2-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 04/08/2025
Date Tested: 04/08/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Tested 3.5%
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
3.5 %
|
|
Percent Air Voids 2
|
3.5 %
|
|
Percent Air Voids 3
|
3.6 %
|
|
Average Percent Air Voids
|
3.5 %
|
DIME Test ID: 2025-04-06-2-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 04/16/2025
Date Tested: 04/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target WET >70 psi and DRY>100 psi
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
137 psi
|
|
Average Wet Tensile Strength
|
99 psi
|
|
Tensile Strength Ratio
|
0.72
|
DIME Test ID: 2025-04-06-2-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 04/09/2025
Date Tested: 04/09/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target < 12.7 mm / Tested 1.33 mm
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
113 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>10000
|
|
Stripping Inflection Point (Wheel B)
|
>10000
|
|
Maximum impression at 5000 passes (left wheel)
|
0.99 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
1.04 mm
|
|
Average impression at 5000 passes (left/right avg)
|
1.02 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
1.31 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
1.34 mm
|
|
Average impression at 10000 passes (left/right avg)
|
1.33 mm
|
|
Average impression at 15000 passes (left/right avg)
|
no data
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|
DIME Test ID: 2025-04-06-2-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/11/2025
Date Tested: 04/10/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: RAP Oil Content (3)
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4023 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5668 g
|
|
Mass of HMA Sample prior to ignition
|
1645 g
|
|
Corrected Asphalt Binder Content
|
6.91 %
|
|
Mass Loss
|
113.7 g
|
|
Mass of aggregate remaining after ignition
|
1531.3 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|