Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2025-04-03-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Stock
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/03/2025
Date that the sample was received by the laboratory/organization performing the testing: 04/03/2025
The quantity of what the sample constitutes: 2500
A brief description of the sample: ASTM F959 7/8" Direct Tension Indicator
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales
Rocap Number(s):
Heat Number(s): 32409610
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s): 783G48
Bolt Specification: N/A
Bolt Length(s):
Nut Specification: N/A
Washer Specification: ASTM F959 Type 325
Finish: Mechanical Galvanized
Diameter/Size: 7/8"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
DIME Test ID: 2025-04-03-1-1
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/10/2025
Date Tested: 06/10/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
783G48
|
|
Finish Coating
|
ASTM B695 - Mech Galv
|
|
Product Markings
|
no data
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.5 mils
|
DIME Test ID: 2025-04-03-1-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/10/2025
Date Tested: 06/10/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
783G48
|
|
Finish Coating
|
ASTM B695 - Mech Galv
|
|
Product Markings
|
no data
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.2 mils
|
DIME Test ID: 2025-04-03-1-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/10/2025
Date Tested: 06/10/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
783G48
|
|
Finish Coating
|
ASTM B695 - Mech Galv
|
|
Product Markings
|
no data
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.6 mils
|