Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000612 DEA: 120R57U4 EFIS: 1223000131
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-405-11.4/24.2
Work Description: PLACE JPCP (RSC) AND RHMA, AND MODIFY ELECTRICAL SYSTEMS.
Location Description: ORANGE COUNTY FROM HARBOR BOULEVARD UNDERCROSSING IN COSTA MESA TO LOS ANGELES COUNTY LINE AT ROSSMOOR
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 9050 Norris Ave. #200, Westlake Village, CA 91361
Resident Engineer: Dennis Nguyen Structure Rep.: maribel Munoz Blanco
DIME Sample ID: 2025-03-24-43
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 03/24/2025
Date that the sample was received by the laboratory/organization performing the testing: 03/27/2025
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Irwindale
Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2025-03-24-43-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 04/03/2025
Date Tested: 04/02/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
ASTM Thermometer used?
|
C
|
|
Softening Point Sample 1
|
55 C
|
|
Softening Point Sample 2
|
55 C
|
|
Bath Liquid
|
freshly boiled distilled water
|
|
Minutes Reaction
|
no data
|
DIME Test ID: 2025-03-24-43-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 04/03/2025
Date Tested: 04/02/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Determination
|
Unworked Penetration
|
|
Unworked Penetration
|
36 0.1 mm
|
DIME Test ID: 2025-03-24-43-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 04/03/2025
Date Tested: 04/02/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Temperature
|
25 C
|
|
Ball Penetration (P1)
|
5 mm
|
|
Final Dial reading (F1)
|
69 mm
|
|
Ball Penetration (P2)
|
4 mm
|
|
Final Dial reading (F2)
|
71 mm
|
|
Ball Penetration (P3)
|
4 mm
|
|
Final Dial reading (F3)
|
71 mm
|
|
Resilience 1
|
36 %
|
|
Resilience 2
|
33 %
|
|
Resilience 3
|
33 %
|
|
Average Resilience
|
34 %
|
|
Minutes Reaction
|
no data
|