Print Report | Back to Sample Detail

Sample Record for 2025-03-18-31

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994539 DEA: 021H58U4 EFIS: 0223000059 QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-70-58.2/R78.4
Work Description: RECONSTRUCT ROADWAY, HMA PAVING, DRAINAGE AND ELECTRICAL WORK.
Location Description: PLUMAS COUNTY AT AND NEAR CROMBERG FROM GILL RANCH ROAD TO 0.2 MILE WEST OF BIG GRIZZLY CREEK BRIDGE
Contractor Name: MERCER-FRASER COMPANY
Contractor Address: PO Box 1006, Eureka, CA 95502
Resident Engineer: Mike Zdenek Structure Rep.: Brandon Thurber

Sample Information

DIME Sample ID: 2025-03-18-31
TL Number from the TL Form:
Sample Submitted By Organization: Precast Unlimited Inc.
Sample Organization Contact: (530) 243-6477
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 03/18/2025
Date that the sample was received by the laboratory/organization performing the testing: 03/18/2025
The quantity of what the sample constitutes: 1194.4g
A brief description of the sample: 3/8" x #8
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Shasta Ready Mix

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-45-0019
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Shasta Ready Mix Stockpile
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/8 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2025-03-18-31-1
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 03/28/2025
Date Tested: 03/24/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? 0.375 in x No. 8 - Coarse Aggregate
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 97 %
Cumulative percent passing the #4 sieve 15 %
Cumulative percent passing the #8 sieve 3 %

Test 2 of 2

DIME Test ID: 2025-03-18-31-2
Test Method: ASTM C566-19: Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying
Verified Date: 03/28/2025
Date Tested: 03/21/2025
Submitted By Organization: Precast Unlimited Inc.
Organization Address: 16538 Clear Creek Rd.,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: chase@precastunlimited.com
Organization Phone: 1 (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total evaporable moisture content 4.7 %