Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000320 DEA: 11430324 EFIS: 1118000102
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-14.6/23.7
Work Description: MODIFY ELECTRICAL, CONCRETE PAVEMENT, DRAINAGE AND SIGNS.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM ROUTE 805/15 SEPARATION TO 0.1 MILE NORTH OF ROUTE 805/52 SEPARATION
Contractor Name: COFFMAN SPECIALTIES, INC.
Contractor Address: 9685 VIA EXCELENCIA STE 200, SAN DIEGO, CA 92126
Resident Engineer: Art Pannu Structure Rep.: Anh Ma
DIME Sample ID: 2025-03-26-4
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 03/26/2025
Date that the sample was received by the laboratory/organization performing the testing: 03/26/2025
The quantity of what the sample constitutes: 3 cylinders
A brief description of the sample: Concrete
From where was the sample collected: Job Site
Laboratory sample identification: 25-3-26-4
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Coffman Specialties, Inc
The concrete mix design number: 2010-007
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Not Provided
Concrete batch plant:
The fabricator/manufacturer designation for the sample: Set 2
A detailed description of where the material sample was collected: On site
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2025-03-26-4-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/08/2025
Date Tested: 04/04/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 3 @ 10 days, 650 psi
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
5.99 in
|
|
Average diameter of cylinder 2
|
5.99 in
|
|
Average diameter of cylinder 3
|
5.99 in
|
|
Cross sectional area of cylinder 1
|
28.18 in^2
|
|
Cross sectional area of cylinder 2
|
28.18 in^2
|
|
Cross sectional area of cylinder 3
|
28.18 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5180 psi
|
|
Maximum load on cylinder 1
|
161515 lb
|
|
Maximum load on cylinder 2
|
119475 lb
|
|
Maximum load on cylinder 3
|
157210 lb
|
|
Compressive strength of cylinder 1
|
5731.5 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
4239.7 psi
|
|
Compressive strength of cylinder 3
|
5578.8 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
10 days
|
|
Age of specimen in hours
|
no data0 hours
|