Sample Record for 2025-03-17-20

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993544 DEA: 07324904 EFIS: 0716000079 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-20.1/36.0
Work Description: UPGRADE AND REPAIR THREE EXISTING PUMP PLANTS.
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM HUMBOLDT STREET UNDERPASS TO SHELDON STREET OVERCROSSING
Contractor Name: Stacy and Witbeck, INC
Contractor Address: 2800 Harbor Bay Parkway, Alameda, CA, 94502
Resident Engineer: Sam Toutounchian Structure Rep.: Kwangsuk Suh

Sample Information

DIME Sample ID: 2025-03-17-20
TL Number from the TL Form: 2025-03-17-5
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 03/17/2025
Date that the sample was received by the laboratory/organization performing the testing: 03/19/2025
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 4X8 PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 25-032
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Stacy and Witbak Construction

Material Information

The concrete mix design number: 557237
The truck number from where the sample was collected: NA
The batch plant ticket number from where the sample was collected: 7221758
Concrete batch plant: Martin Marietta
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-03-17-20-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/25/2025
Date Tested: 03/24/2025
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.01 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.63 in^2
Compressive strength (to nearest 10 psi) 3160 psi
Maximum load on cylinder 1 40483 lb
Maximum load on cylinder 2 39613 lb
Maximum load on cylinder 3 39204 lb
Compressive strength of cylinder 1 3220.6 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3151.4 psi
Compressive strength of cylinder 3 3104 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours