Print Report | Back to Sample Detail

Sample Record for 2025-03-20-17

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995201 DEA: 061G3104 EFIS: 0623000239 QA Service Level: 1
DIST-CO-RTE-PM: 06-KER-178-20.6/21.6
Work Description: Roadway / retaining wall / slope repairs
Location Description:
Contractor Name: GENUINE ENGINEERING INC
Contractor Address: 11762 De Palma Road,Suite 1C, PMB 225, Corona, CA 92883
Resident Engineer: Travis Landas Structure Rep.: Albert Heredia

Sample Information

DIME Sample ID: 2025-03-20-17
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Sample Organization Contact: 661-549-8281
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 03/20/2025
Date that the sample was received by the laboratory/organization performing the testing: 03/21/2025
The quantity of what the sample constitutes: 0 to 300 cy
A brief description of the sample: PCC cylinders retaining wall
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: 711 materials

Material Information

The concrete mix design number: 750216A6
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: BACK OF THE TRUCK
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2025-03-20-17-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/25/2025
Date Tested: 03/25/2025
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 3810 psi
Maximum load on cylinder 1 48710 lb
Maximum load on cylinder 2 47900 lb
Maximum load on cylinder 3 47240 lb
Compressive strength of cylinder 1 3875.1 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 3810.7 psi
Compressive strength of cylinder 3 3758.2 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 5 days
Age of specimen in hours no data0 hours

Test 2 of 2

DIME Test ID: 2025-03-20-17-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/27/2025
Date Tested: 03/27/2025
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 3.99 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.5 in^2
Compressive strength (to nearest 10 psi) 4230 psi
Maximum load on cylinder 1 52720 lb
Maximum load on cylinder 2 51920 lb
Maximum load on cylinder 3 54490 lb
Compressive strength of cylinder 1 4194.1 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 4130.5 psi
Compressive strength of cylinder 3 4359.2 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours