Project ID: 212861 DEA: 101H2804 EFIS: 1017000190
QA Service Level: 1
DIST-CO-RTE-PM: 10-STA-5-10.7/25.5
Work Description: BRIDGE DECK OVERLAY WITH POLYESTER CONCRETE, REPLACE APPROACH SLABS & JOINT SEALS IN STANISLAUS COUNTY ON STATE ROUTE 5 FROM FINK ROAD UC TO KHALSA ROAD UC.
Location Description: STANISLAUS AND MERCED COUNTIES.
Contractor Name: MYERS & SONS CONSTRUCTION, LLC
Contractor Address: 45 Morrison Avenue, Sacramento, CA 95838
Resident Engineer: Zubair Anwar Structure Rep.: Sai Kasaraneni
DIME Sample ID: 2025-03-12-6
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 03/12/2025
Date that the sample was received by the laboratory/organization performing the testing: 03/14/2025
The quantity of what the sample constitutes: 10 Tankers
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000154KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2025-03-12-6-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 04/29/2025
Date Tested: 04/23/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2025-03-12-6-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 04/29/2025
Date Tested: 04/23/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Density Units
|
pounds/gallons
|
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2025-03-12-6-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 04/29/2025
Date Tested: 04/11/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens tested
|
6
|
|
Conditioning procedure
|
18/25/50+5/70
|
|
Speed of testing
|
0.45 in/min
|
|
Sample 1 Width
|
0.522 in
|
|
Sample 1 Ultimate strength
|
2872.8 psi
|
|
Sample 1 Thickness
|
0.244 in
|
|
Sample 1 Area
|
0.1274 in^2
|
|
Sample 1 Ultimate Strength Actual
|
366 lbs
|
|
Sample 1 percent elongation
|
65 %
|
|
Sample 1 Time
|
no data0 MM:SS
|
|
Sample 2 Width
|
0.519 in
|
|
Sample 2 Thickness
|
0.245 in
|
|
Sample 2 Area
|
0.1272 in^2
|
|
Sample 2 Ultimate strength
|
2838.1 psi
|
|
Sample 2 Ultimate Strength Actual
|
361 lbs
|
|
Sample 2 percent elongation
|
62 %
|
|
Sample 2 Time
|
no data0 MM:SS
|
|
Sample 3 Width
|
0.503 in
|
|
Sample 3 Thickness
|
0.244 in
|
|
Sample 3 Area
|
0.1227 in^2
|
|
Sample 3 Ultimate strength
|
2844.3 psi
|
|
Sample 3 Ultimate Strength Actual
|
349 lbs
|
|
Sample 3 percent elongation
|
62 %
|
|
Sample 3 Time
|
no data0 MM:SS
|
|
Sample 4 Width
|
0.505 in
|
|
Sample 4 Thickness
|
0.246 in
|
|
Sample 4 Area
|
0.1242 in^2
|
|
Sample 4 Ultimate strength
|
2938.8 psi
|
|
Sample 4 Ultimate Strength Actual
|
365 lbs
|
|
Sample 4 percent elongation
|
65 %
|
|
Sample 4 Time
|
no data0 MM:SS
|
|
Sample 5 Width
|
0.514 in
|
|
Sample 5 Thickness
|
0.243 in
|
|
Sample 5 Area
|
0.1249 in^2
|
|
Sample 5 Ultimate strength
|
2834.3 psi
|
|
Sample 5 Ultimate Strength Actual
|
354 lbs
|
|
Sample 5 percent elongation
|
61 %
|
|
Sample 5 Time
|
no data0 MM:SS
|
|
Sample 6 Width
|
0.505 in
|
|
Sample 6 Thickness
|
0.251 in
|
|
Sample 6 Area
|
0.1268 in^2
|
|
Sample 6 Ultimate strength
|
2862.8 psi
|
|
Sample 6 Ultimate Strength Actual
|
363 lbs
|
|
Sample 6 percent elongation
|
64 %
|
|
Sample 6 Time
|
no data0 MM:SS
|
|
Ultimate Strength Average
|
2865 psi
|
|
Percent Elongation Average
|
63 %
|
DIME Test ID: 2025-03-12-6-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 04/29/2025
Date Tested: 04/23/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Mean of two volatile content determination
|
46
|
DIME Test ID: 2025-03-12-6-5
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 04/29/2025
Date Tested: 04/23/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Diameter of lid
|
154.11 mm
|
|
Room Temperature
|
75 f
|
|
Tare weight
|
no data
|
|
Initial weight
|
100.21 grams
|
|
Weight at 5 minutes
|
100.04 grams
|
|
Weight at 10 minutes
|
99.89 grams
|
|
Weight at 15 minutes
|
99.75 grams
|
|
Weight at 20 minutes
|
99.61 grams
|
|
Weight at 25 minutes
|
99.47 grams
|
|
Weight at 30 minutes
|
99.32 grams
|
|
Final weight
|
99.32 grams
|
|
Total weight loss
|
0.89 grams
|
|
Calculated radius of gallon can lid in cm
|
7.706 cm
|
|
Lid Factor
|
53.603 m^2
|
|
Volatile emission
|
47.707 grams/m^2
|