Print Report | Back to Sample Detail

Sample Record for 2025-03-14-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000403 DEA: 120K91U4 EFIS: 1222000031 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-91-R9.2/R11.4
Work Description: CONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location Description: ORANGE COUNTY IN ANAHEIM FROM 0.9 MILE WEST TO 1.3 MILES EAST OF LAKEVIEW AVENUE OVERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 16700 Valley View Avenue Suite 300
Resident Engineer: Steve Kinaly Structure Rep.: Wei-Jen Lee

Sample Information

DIME Sample ID: 2025-03-14-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 03/14/2025
Date that the sample was received by the laboratory/organization performing the testing: 03/19/2025
The quantity of what the sample constitutes: 218
A brief description of the sample: Ductile Iron Casting
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dywidag

Material Information

Heat Number (s): H214
Part Number (s): 68 27 172 90
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Farrar Corporation
Prestressing Manufacturer: Dywidag

Test Results

Test 1 of 1

DIME Test ID: 2025-03-14-4-1
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 04/21/2025
Date Tested: 04/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1H2140.5040.1995684001134007Atlas
UTM NA
Temperature 0 f