Print Report | Back to Sample Detail

Sample Record for 2025-01-23-37

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676 QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-80-R10.4/30.2
Work Description: Highway widening, overhead signs, and electronic toll system.
Location Description: In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
Contractor Name: O.C. JONES & SONS, INC.
Contractor Address: 1520 Fourth Street, Berkeley, CA 94710
Resident Engineer: Justen Tatum Structure Rep.: Kelsey Littell

Sample Information

DIME Sample ID: 2025-01-23-37
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Fairfield Construction Field Office 59-545
Sample Organization Contact: 510-714-7055
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 01/23/2025
Date that the sample was received by the laboratory/organization performing the testing: 03/17/2025
The quantity of what the sample constitutes: 3 cylinders
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Soundwall 2 16" piles
The fabricator/manufacturer/facility name: Cemex Fairfield

Material Information

The concrete mix design number: 1615674
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 31491507
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: back of truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-01-23-37-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/25/2025
Date Tested: 03/24/2025
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: Samples delivered to Vallejo Lab on 03/20/2025
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 1 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 5790 psi
Maximum load on cylinder 1 71020 lb
Maximum load on cylinder 2 72151 lb
Maximum load on cylinder 3 75231 lb
Compressive strength of cylinder 1 5650.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 5740.0 psi
Compressive strength of cylinder 3 5980 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) Samples delivered to Vallejo Lab on 03/20/2025
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 61 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2025-01-23-37-1ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete03/17/202501/23/2025lam nguyenCT D04 - Fairfield Construction Field Office 59-54561F tested by RMA
2025-01-23-37-2ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete03/17/202501/23/2025lam nguyenCT D04 - Fairfield Construction Field Office 59-5455 1/2" tested by RMA