Print Report | Back to Sample Detail

Sample Record for 2024-12-09-67

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995447 DEA: 060X2604 EFIS: 0618000045 QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-198-1.6/43.9
Work Description: REMOVE, INSTALL, AND REPAIR DRAINAGE FACILITIES.
Location Description: TULARE COUNTY IN AND NEAR VISALIA AT VARIOUS LOCATIONS FROM 1.6 MILES EAST OF KINGS COUNTY LINE TO 0.2 MILE WEST OF SEQUOIA NATIONAL PARK BOUNDARY
Contractor Name: A. TEICHERT & SON, INC. DBA TEICHERT CONSTRUCTION
Contractor Address: 5771 S. Toyota Pl., Fresno, CA 93725
Resident Engineer: Chris Wilfong Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-12-09-67
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Visalia Field Laboratory
Sample Organization Contact: (559) 974-1304
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/09/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/10/2024
The quantity of what the sample constitutes: Concrete Cylinders
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 56
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Not Given

Material Information

The concrete mix design number: 175457
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Not Given
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: QC Supplied
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2024-12-09-67-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/07/2025
Date Tested: 01/06/2025
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 W Roosevelt Ave,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: paul.klinker@dot.ca.gov
Organization Phone: (559) 974-1304
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 5250 psi
Maximum load on cylinder 1 66269 lb
Maximum load on cylinder 2 66177 lb
Maximum load on cylinder 3 65507 lb
Compressive strength of cylinder 1 5272.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 5264.7 psi
Compressive strength of cylinder 3 5211.4 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours