Project Information

Project ID: 993815 DEA: 081C0814 EFIS: 0816000086 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-R60.7/R74.3
Work Description: I-10 PAVEMENT REHABILITATION (SEGMENT 1) PROJECT
Location Description: Coachella
Contractor Name: COFFMAN SPECIALTIES, INC
Contractor Address: 4375 JUTLAND DRIVE STE 260, SAN DIEGO CA 92117
Resident Engineer: Michael Sergah Structure Rep.: Al Alina

Sample Information

DIME Sample ID: 2025-02-27-6
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 02/27/2025
Date that the sample was received by the laboratory/organization performing the testing: 02/28/2025
The quantity of what the sample constitutes: 12 BOXES OF HMA, 2 QTS PG58-22
A brief description of the sample: 3/4" HMA A SP R24 .5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0148A-25
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marieta Coachella

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 43417155
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2025-02-27-6-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/08/2025
Date Tested: 03/06/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2133.8 g
Corrected Asphalt Binder Content 4.57 %
Mass Loss 109.1 g
Correction Factor (Percent by mass of HMA Specimen) 0.4 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %