Print Report | Back to Sample Detail

Sample Record for 2025-02-05-14

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994309 DEA: 033H5404 EFIS: 0318000012 QA Service Level: 1
DIST-CO-RTE-PM: 03-BUT-70-46.0/47.0
Work Description: RAISE ALIGNMENT, PLACE HMA, STRUCTURAL CONCRETE & BRIDGE RAIL.
Location Description: BUTTE COUNTY NEAR PARADISE FROM 0.8 MILE WEST OF SHADY REST AREA TO 0.2 MILE EAST OF SHADY REST AREA
Contractor Name: VIKING CONSTRUCTION COMPANY, INC.
Contractor Address: 11315 SUNRISE GOLD CIR. #A, RANCHO CORDOVA CA 95742
Resident Engineer: Daniel Rechs Structure Rep.: Adam Scardaci

Sample Information

DIME Sample ID: 2025-02-05-14
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 02/05/2025
Date that the sample was received by the laboratory/organization performing the testing: 02/06/2025
The quantity of what the sample constitutes: 80 drums
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000149KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia

Material Information

Mfg. Lot Number(s): AZ5A00119D
Batch number: AZ5A00119D
Mix number: AZ5A00119D

Test Results

Test 1 of 5

DIME Test ID: 2025-02-05-14-1
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 04/29/2025
Date Tested: 04/21/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 8.9

Test 2 of 5

DIME Test ID: 2025-02-05-14-3
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 04/29/2025
Date Tested: 04/21/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 46

Test 3 of 5

DIME Test ID: 2025-02-05-14-4
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 04/29/2025
Date Tested: 04/23/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 154.14 mm
Room Temperature 75 f
Tare weight no data
Initial weight 99.98 grams
Weight at 5 minutes 99.79 grams
Weight at 10 minutes 99.63 grams
Weight at 15 minutes 99.48 grams
Weight at 20 minutes 99.33 grams
Weight at 25 minutes 99.17 grams
Weight at 30 minutes 99.03 grams
Final weight 99.03 grams
Total weight loss 0.95 grams
Calculated radius of gallon can lid in cm 7.707 cm
Lid Factor 53.59 m^2
Volatile emission 50.911 grams/m^2

Test 4 of 5

DIME Test ID: 2025-02-05-14-5
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 04/29/2025
Date Tested: 04/23/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity 84.5

Test 5 of 5

DIME Test ID: 2025-02-05-14-6
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 04/29/2025
Date Tested: 04/29/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 6
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.515 in
Sample 1 Ultimate strength 2872.7 psi
Sample 1 Thickness 0.25 in
Sample 1 Area 0.1288 in^2
Sample 1 Ultimate Strength Actual 370 lbs
Sample 1 percent elongation 66 %
Sample 1 Time no data0 MM:SS
Sample 2 Width 0.506 in
Sample 2 Thickness 0.25 in
Sample 2 Area 0.1265 in^2
Sample 2 Ultimate strength 2924.9 psi
Sample 2 Ultimate Strength Actual 370 lbs
Sample 2 percent elongation 67 %
Sample 2 Time no data0 MM:SS
Sample 3 Width 0.506 in
Sample 3 Thickness 0.244 in
Sample 3 Area 0.1235 in^2
Sample 3 Ultimate strength 2931.2 psi
Sample 3 Ultimate Strength Actual 362 lbs
Sample 3 percent elongation 65 %
Sample 3 Time no data0 MM:SS
Sample 4 Width 0.515 in
Sample 4 Thickness 0.243 in
Sample 4 Area 0.1251 in^2
Sample 4 Ultimate strength 2821.7 psi
Sample 4 Ultimate Strength Actual 353 lbs
Sample 4 percent elongation 62 %
Sample 4 Time no data0 MM:SS
Sample 5 Width 0.507 in
Sample 5 Thickness 0.249 in
Sample 5 Area 0.1262 in^2
Sample 5 Ultimate strength 2662.4 psi
Sample 5 Ultimate Strength Actual 336 lbs
Sample 5 percent elongation 57 %
Sample 5 Time no data0 MM:SS
Sample 6 Width 0.511 in
Sample 6 Thickness 0.247 in
Sample 6 Area 0.1262 in^2
Sample 6 Ultimate strength 2765.5 psi
Sample 6 Ultimate Strength Actual 349 lbs
Sample 6 percent elongation 57 %
Sample 6 Time no data0 MM:SS
Ultimate Strength Average 2830 psi
Percent Elongation Average 62 %