Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994121 DEA: 120P68U4 EFIS: 1218000105
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-1-13.0/33.7
Work Description: COLD PLANE, PLACE RHMA AND MODIFY CURB RAMPS AND ELECTRICAL SYSTEMS.
Location Description: ORANGE COUNTY AT VARIOUS LOCATIONS FROM CRYSTAL HEIGHTS DRIVE TO LOS ANGELES/ORANGE COUNTY LINE
Contractor Name: CHUMO CONSTRUCTION INC.
Contractor Address: 4949 2nd St., Fallbrook, CA 92028
Resident Engineer: Christopher Blanco Structure Rep.: Vian Ghazi
DIME Sample ID: 2025-02-06-19
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 02/06/2025
Date that the sample was received by the laboratory/organization performing the testing: 02/12/2025
The quantity of what the sample constitutes: 4 bags of comb agg, 1 bag crumb rubber scrap, 1 bag of hi nat
A brief description of the sample: JMF 3/4" RWMA-G-SP 0.4% EVO
From where was the sample collected: Manufacturer
Laboratory sample identification: 0129G-25
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA - Corona/ SJR/ Ingevity
Source Identification (SMARA, name of Pit or Job Site): 91-33-0005
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Belt Cut at All American Corona Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: 108835
Lot number:
Sublot number:
Aggregate Mix Number:
DIME Test ID: 2025-02-06-19-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 01/30/2026
Date Tested: 02/25/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test: Combined Virgin Aggregate Gradation
Test Result Compliance:
Additional Comments When Verified:
|
What type of gradation is being tested?
|
Combined Gradation
|
|
Cumulative percent passing the 2 in. sieve
|
no data0 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
95 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
82 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
68 %
|
|
Cumulative percent passing the #4 sieve
|
33 %
|
|
Cumulative percent passing the #8 sieve
|
19 %
|
|
Cumulative percent passing the #16 sieve
|
13 %
|
|
Cumulative percent passing the #30 sieve
|
9 %
|
|
Cumulative percent passing the #50 sieve
|
5 %
|
|
Cumulative percent passing the #100 sieve
|
3 %
|
|
Cumulative percent passing the #200 sieve
|
1.9 %
|
DIME Test ID: 2025-02-06-19-4
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 01/30/2026
Date Tested: 02/26/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2025-02-06-19-5
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 01/30/2026
Date Tested: 02/25/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Bulk specific gravity
|
2.651
|
|
Bulk specific gravity (SSD Basis)
|
2.691
|
|
Apparent specific gravity
|
2.762
|
|
Absorption
|
1.5 %
|
DIME Test ID: 2025-02-06-19-6
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 01/30/2026
Date Tested: 02/18/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Basis for relative density testing
|
Bulk
|
|
Specific Gravity
|
2.747
|
|
Absorption
|
0.6 %
|
DIME Test ID: 2025-02-06-19-7
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 01/30/2026
Date Tested: 02/26/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Grading designation
|
B
|
|
Mass of sample on No.12 sieve (after 500 revolutions)
|
4291 grams
|
|
Percent loss after 100 revolutions
|
3 %
|
|
Percent loss after 500 revolutions
|
14 %
|
DIME Test ID: 2025-02-06-19-8
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 01/30/2026
Date Tested: 02/21/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Method
|
1 - Combined Fracture Determination
|
|
Aggregate Size and Fracture Type
|
Coarse 1 and 2 Faced and Fine 1 Faced
|
|
Percentage of fractured, coarse, 2 faced particles tested
|
100 %
|
|
Percentage of fractured, coarse, 1 faced particles tested
|
100 %
|
|
Percentage of fractured, fine, 1 faced particles tested
|
100 %
|
DIME Test ID: 2025-02-06-19-9
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 01/30/2026
Date Tested: 02/21/2025
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
What test method is performed?
|
Method A
|
|
Bulk dry specific gravity
|
2.651
|
|
Average uncompacted voids
|
45.4 %
|