Sample Record for 2025-01-30-6
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 995492 DEA: 07358204 EFIS: 0719000107
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5823-
Work Description: PROVIDE BUILDING WORK AT A MAINTENANCE STATION.
Location Description: LOS ANGELES COUNTY IN LONG BEACH AT THE PACIFIC PLACE MAINTENANCE STATION AT NORTH 3725 PACIFIC PLACE
Contractor Name: MERCER-FRASER COMPANY
Contractor Address: P O BOX 1006, EUREKA, CA 95502-1006
Resident Engineer: Jeffrey Townsend Structure Rep.: Sami Deeb
Sample Information
DIME Sample ID: 2025-01-30-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 01/30/2025
Date that the sample was received by the laboratory/organization performing the testing: 01/30/2025
The quantity of what the sample constitutes: 23 Assemblies
A brief description of the sample: 5/8" Fastener Assembly
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: C & K Johnson Industries
Material Information
Rocap Number(s):
Heat Number(s): Bolt-10837860
Nut- 20894500
Washer-22409500
Nut Mfg. Lot Number(s): E746P1
Washer Mfg. Lot Number(s): E6528
Bolt Specification: ASTM A325
Bolt Length(s): 2-1/4"
Nut Specification: ASTM A563 Grade DH
Washer Specification: ASTM F436
Finish:
Diameter/Size: 5/8"
Bolt Mfg. Lot Number: E244L1
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
Test Results
Test 1 of 7
DIME Test ID: 2025-01-30-6-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 03/05/2025
Date Tested: 02/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
10837860
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
2.25 in
|
|
Pitch Diameter
|
0.5754 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 2 of 7
DIME Test ID: 2025-01-30-6-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/05/2025
Date Tested: 02/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
10837860
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
2.25 in
|
|
Measurement Average
|
3.1 mils
|
Test 3 of 7
DIME Test ID: 2025-01-30-6-3
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/05/2025
Date Tested: 02/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
10837860
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
2.25 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
29.3
|
|
Spacing
|
Ok
|
Test 4 of 7
DIME Test ID: 2025-01-30-6-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/05/2025
Date Tested: 02/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
20894500
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.9 mils
|
Test 5 of 7
DIME Test ID: 2025-01-30-6-5
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/05/2025
Date Tested: 02/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
20894500
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
31.2
|
|
Spacing
|
Ok
|
Test 6 of 7
DIME Test ID: 2025-01-30-6-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/05/2025
Date Tested: 02/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
22409500
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.9 mils
|
Test 7 of 7
DIME Test ID: 2025-01-30-6-7
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/05/2025
Date Tested: 02/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
22409500
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
42.1
|
|
Spacing
|
Ok
|