Print Report | Back to Sample Detail

Sample Record for 2025-01-16-33

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000144 DEA: 061E2204 EFIS: 0621000227 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-180-R65.3/R66.3
Work Description: HIGH TENSION CABLE BARRIER AND VEGETATION CONTROL.
Location Description: FRESNO COUNTY NEAR FRESNO FROM TEMPERANCE AVENUE UNDERCROSSING TO 0.1 MILE WEST OF DE WOLF AVENUE.
Contractor Name: CORAL CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: Alaa Ghoneim Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-01-16-33
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 01/16/2025
Date that the sample was received by the laboratory/organization performing the testing: 01/16/2025
The quantity of what the sample constitutes: 10 Cy
A brief description of the sample: 4x8 cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex

Material Information

The concrete mix design number: 1416245
The truck number from where the sample was collected: 76217
The batch plant ticket number from where the sample was collected: 41072
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: R21 STA 100+00 - 102+24
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 3

DIME Test ID: 2025-01-16-33-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/30/2025
Date Tested: 01/30/2025
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.02 in
Average diameter of cylinder 2 4.01 in
Average diameter of cylinder 3 4.01 in
Cross sectional area of cylinder 1 12.69 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.63 in^2
Compressive strength (to nearest 10 psi) 4260 psi
Maximum load on cylinder 1 54100 lb
Maximum load on cylinder 2 51790 lb
Maximum load on cylinder 3 55700 lb
Compressive strength of cylinder 1 4263.2 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 4100.6 psi
Compressive strength of cylinder 3 4410.1 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 14 days
Age of specimen in hours no data0 hours

Test 2 of 3

DIME Test ID: 2025-01-16-33-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/30/2025
Date Tested: 01/30/2025
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test: Required strenght 4000 psi
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4290 psi
Maximum load on cylinder 1 54100 lb
Maximum load on cylinder 2 51790 lb
Maximum load on cylinder 3 55700 lb
Compressive strength of cylinder 1 4303.9 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 4120.1 psi
Compressive strength of cylinder 3 4431.2 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 14 days
Age of specimen in hours no data0 hours

Test 3 of 3

DIME Test ID: 2025-01-16-33-4
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 02/13/2025
Date Tested: 02/13/2025
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4970 psi
Maximum load on cylinder 1 61350 lb
Maximum load on cylinder 2 64030 lb
Maximum load on cylinder 3 62090 lb
Compressive strength of cylinder 1 4880.7 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 5093.9 psi
Compressive strength of cylinder 3 4939.5 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2025-01-16-33-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders01/30/2025Not scheduledJonathon ChaneyCT D06 - Millbrook Field Laboratory