Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995031 DEA: 023H82U4 EFIS: 0223000011
QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS-44-0.0/37.2
Work Description: REPLACE AC SURFACING, PLACE RHMA, HMA, THERMOPLASTIC TRAFFIC STRIPE.
Location Description: LASSEN COUNTY ABOUT 9 MILES EAST OF OLD STATION FROM SHASTA COUNTY LINE TO ROUTE 36
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: 24339 Hwy 89 N, Burney, CA 96013
Resident Engineer: Edward Worden Structure Rep.: Unknown
DIME Sample ID: 2024-08-12-123
TL Number from the TL Form: 692873
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/12/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/13/2024
The quantity of what the sample constitutes: 6 Boxes
A brief description of the sample: 3/4" RHMA-G
From where was the sample collected: Manufacturer
Laboratory sample identification: D79686
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction and Materials - Ward Lake Plant (Litchfield, CA)
DIME Test ID: 2024-08-12-123-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 01/28/2025
Date Tested: 12/16/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.424
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7331.7 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2586.9 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8851.5 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.424
|
|
Theoretical maximum density at 25°C (77°F)
|
2417 kg/m^3
|
DIME Test ID: 2024-08-12-123-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 01/28/2025
Date Tested: 12/17/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=7.31%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3028.8 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5140.1 g
|
|
Mass of HMA Sample prior to ignition
|
2111.3 g
|
|
Corrected Asphalt Binder Content
|
7.31 %
|
|
Mass Loss
|
173.2 g
|
|
Mass of aggregate remaining after ignition
|
1938.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.75 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
538 C
|