Print Report | Back to Sample Detail

Sample Record for 2024-12-18-42

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000187 DEA: 112N1674 EFIS: 1122000280 QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-86-R34.8/64.1
Work Description: POLYESTER CONCRETE OVERLAY, APPLY METHACRYLATE,& JOINT SEALS.
Location Description: IMPERIAL COUNTY AT VARIOUS LOCATIONS FROM TRIFOLIUM CANAL BRIDGE (58-0017) TO GODETIA DITCH BRIDGE (58-0067)
Contractor Name: TRUESDELL CORPORATION OF CALIFORNIA, INC.
Contractor Address: 1310 W 23RD ST, TEMPE AZ 85282
Resident Engineer: Guillermo Sillas Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-12-18-42
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 12/18/2024
Date that the sample was received by the laboratory/organization performing the testing: 01/15/2025
The quantity of what the sample constitutes: 6 bags
A brief description of the sample: Plant Sample
From where was the sample collected: Supplier
Laboratory sample identification: 1502-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: API Gateway

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-13-0057
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number: 39

Test Results

Test 1 of 5

DIME Test ID: 2024-12-18-42-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 01/30/2025
Date Tested: 01/28/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 90 %
Cumulative percent passing the 3/8 in. sieve 23 %
Cumulative percent passing the #4 sieve 2 %
Cumulative percent passing the #8 sieve 2 %
Cumulative percent passing the #16 sieve 2 %
Cumulative percent passing the #30 sieve 1 %
Cumulative percent passing the #50 sieve 1 %
Cumulative percent passing the #100 sieve 1 %
Cumulative percent passing the #200 sieve 1.4 %

Test 2 of 5

DIME Test ID: 2024-12-18-42-2
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 01/30/2025
Date Tested: 01/28/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 94 %
Cumulative percent passing the #4 sieve 33 %
Cumulative percent passing the #8 sieve 4 %
Cumulative percent passing the #16 sieve 1 %
Cumulative percent passing the #30 sieve no data0 %
Cumulative percent passing the #50 sieve no data0 %
Cumulative percent passing the #100 sieve no data0 %
Cumulative percent passing the #200 sieve 0.2 %

Test 3 of 5

DIME Test ID: 2024-12-18-42-3
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 01/30/2025
Date Tested: 01/28/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
What type of gradation is being tested? Fine Aggregate
Total mass of sample tested 514 grams
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 98 %
Cumulative percent passing the #8 sieve 20 %
Cumulative percent passing the #16 sieve 1 %
Cumulative percent passing the #30 sieve 1 %
Cumulative percent passing the #50 sieve 1 %
Cumulative percent passing the #100 sieve no data0 %
Cumulative percent passing the #200 sieve 0.4 %

Test 4 of 5

DIME Test ID: 2024-12-18-42-4
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 01/30/2025
Date Tested: 01/28/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
What type of gradation is being tested? Fine Aggregate
Total mass of sample tested 511.2 grams
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 100 %
Cumulative percent passing the #8 sieve 95 %
Cumulative percent passing the #16 sieve 78 %
Cumulative percent passing the #30 sieve 60 %
Cumulative percent passing the #50 sieve 40 %
Cumulative percent passing the #100 sieve 20 %
Cumulative percent passing the #200 sieve 8.4 %

Test 5 of 5

DIME Test ID: 2024-12-18-42-6
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 01/30/2025
Date Tested: 01/28/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 72