Sample Record for 2025-01-22-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000208 DEA: 07346004 EFIS: 0718000070 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-101-11.0/23.5
Work Description: CONSTRUCT MVPS, PAVE BEYOND THE GORE, INSTALL GATES & CABLE RAILING.
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM NORTH OF VINELAND AVENUE TO NORTH OF WINNETKA AVENUE
Contractor Name: YAKAR
Contractor Address: Unknown
Resident Engineer: VLADIMIR GURFINKEL Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2025-01-22-1
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 01/22/2025
Date that the sample was received by the laboratory/organization performing the testing: 01/16/2025
The quantity of what the sample constitutes: 10cuyd
A brief description of the sample: 6 x 12 LCB Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 25-0202
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Robertson Ready Mix

Material Information

The concrete mix design number: RRM22144
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1362506
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2025-01-22-1-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/22/2025
Date Tested: 01/22/2025
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 6
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Average diameter of cylinder 3 6.00 in
Average diameter of cylinder 4 6.00 in
Average diameter of cylinder 5 6.00 in
Average diameter of cylinder 6 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Cross sectional area of cylinder 3 28.27 in^2
Cross sectional area of cylinder 4 28.27 in^2
Cross sectional area of cylinder 5 28.27 in^2
Cross sectional area of cylinder 6 28.27 in^2
Compressive strength (to nearest 10 psi) 670 psi
Maximum load on cylinder 1 19039 lb
Maximum load on cylinder 2 18710 lb
Maximum load on cylinder 3 18348 lb
Maximum load on cylinder 4 19022 lb
Maximum load on cylinder 5 19447 lb
Maximum load on cylinder 6 18844 lb
Type of fracture pattern of cylinder 1 5
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Type of fracture pattern of cylinder 4 5
Type of fracture pattern of cylinder 5 5
Type of fracture pattern of cylinder 6 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Correction factor for cylinder 4 1
Correction factor for cylinder 5 1
Correction factor for cylinder 6 1
Age of specimen 7 days
Age of specimen in hours no data0 hours